CONDUIT

. KNOCKOUTS

FOR SPEAKER

WIRING

TRANSFORMER
ACCESSORY
RECEPTACLE

The input leads are connected to terminals
3 and 4 of the INPUT terminal board (see

Figure 4).

When shipped from the factory, pins 3 and 4
of J1 are strapped together to provide a
600-ohm Input. A 150-ohm Input may be
obtained by removing the strap from pins 3
and 4 and then strapping pin 1 to 4, and
strapping pin 3 to 6 (see Figure 5).

Both the direct and transformer Isolated
inputs may be used simultaneously If Isola­
tion resistors are Installed In either or both

input lines, to prevent one Input source

from short circuiting to the other.

150 ÍÍ WIRING

600Í2 WIRING

I

I

VOLTAGE

' _

RATING BATTERY
NAMEPLATE TERMINAL

BOARD

BATTERY
FUSE

HEAT SINK
SHROUD

FILTER
SWITCH

INPUT

TERMINAL

BOARD

Figure 2. Rear View of 1590 Power Amplifier

Terminal Block TB8/TB9 Connections

Transformer T1

Wire Color

100 V

120 V

240V

Brown

TB9-4

TB8-4

TB8-4

White

TB8-4

TB9-4

TB9-2

Black

TB9-7

TB9-7

TB9-5

White-Brown

TB9-1

TB8-3

TB9-4

White-Black

TB9-8

TB9-8

TB9-8

Permanent AC Power Connections*

Pilot Light S2-4

AC Cord (black)
AC Cord (white)
Switch SW2-3
Fuse FI-2
Capacitor C7
Capacitor C6

TB9-6
TB8-9
TB9-9
TB8-5
TB8-8
TB9-10
TB8-10

*Do not make any wiring changes of

these wire connections when altering
the amplifier for different primary
power operating voltage.

Figure 3. Primary Power Conversion Chart

for 100V, 120V, and 240V 50/60 Hz Operation

4. Select the appropriate voltage rating

label from the rating label strip supplied

with the amplifier. Affix label over pre­
vious

voltage

rating

designation

on

chassis. See Figure 2.

5. When 1590 is strapped for 200V or 240V

line power, replace front panel fuse (FI)

with 2A, 250V, slo-blo type fuse.

6. Close front panel and secure with four

screws previously removed.

Battery Connections

If desired, the 1590 may be connected to an
external 24/28 volt battery with minus (-)
as ground. Terminals for the dc power con­
nections are on TB4 (see Figure 2). If ac

power fails, transfer to dc power Is instan­
taneous, autoamtic and silent. The battery

ower supply Is not operated by the primary
power ON-OFF switch on the front panel. If
switching of battery power Is desired, an
external relay or switch should be provided
by the user.

Input Connections

Input connections may be either direct or

transformer-isolated at the INPUT terminal
board (TB1) (see Figure 2). Direct coupling

Is accomplished by connecting the Input
leads (shielded conductor recommended)

to terminals 1 and 2. Terminal 2 Is ground
(see Figure 4).

For transformer-isolated input, a plug-in
15095A or 15335A Line Transformer must be
plugged into receptacle J1 (see Figure 2).

INPUT

0

0

SHIELD

INPUT

DIRECT CONNECTION

1. For unbalanced high-impedance sources.

2. For bridging unbalanced low-impedance

lines having signal voltages of 0.8V rms
or higher.

TRANSFORMER ISOLATED CONNECTION

1. For balanced or unbalanced lines of 150

or 600 ohms* up to level of

+

15 dBm

(with 15095A Line Transformer),

2. For low-impedance line bridging input or

15,000 ohm line-matching input (with
15335A Line Transformer),

'Factory wiring at receptacle J1 Is for 600

ohms (see Figure 5).

Figure 5. Wiring of Transformer Accessory
Receptacle for Input Impedance of 150 or

600 Ohms. Factory Wiring Is for 600 Ohms

Output Connections

Output transformer taps provide connec­
tions tor 25V (140 watts), 30V, 70.7V, 100V,

140V and 200V distribution systems. Class I
wiring must be used for 100V, 140V and
200V systems. Class II wiring may be used
only for the 30V and 70V systems. Connec­
tions are made at terminal board TB2

located within the chassis (see Figure 6).

Wiring from the speaker system feeds

through the chassis to TB2;

Vi"

conduit

knockouts In the chassis provide access to
output terminals of TB2 and permit termina­
tion as required for Class I wiring (see Fig­
ure 2).

Recommended wire size for 200V operation
is 18 gauge (solid or stranded), for which
power loss Is V

2

dB per 1900 feet of paired

wire. When rigid conduit is not used clamp-
type cable connectors must be Installed in
the conduit knockouts to secure the cable
and provide strain relief.

NOTE-

Typical clamp-type cable connectors
are the Appleton CG-1850 (for Class I
flexible cord such as type SV or SVT),
and the Appleton CG-1250 (for Class

II audio cable usch as Alpha Wire
Corp. No. 1897 [stranded] or No. 1797

[solid]).

Figure 4. Input Connections

After speaker distribution wires are passed
to the site of TB2, quick-connect terminal
clips (T&B type RA257) must be installed.
Be sure that output wiring between knock­
outs and TB2 does not exceed 9 Inches In

length. Strip

'/*"

Insulation from the wire

ends and install the terminal clips. Twist
stranded wire to assure that all strands
properly enter the sleeve of the terminal
clip. Use an appropriate crimping tool (such
as M. Klein & Sons #1002) to crimp the
terminal clips to the wire ends.

Connect terminal clips to the terminals of
TB2 which have the desired Impedance. If
total speaker system Impedance falls be­
tween two rated output values of the 1590,

- 2 -