J4 and j5 – Connect Tech CANPRO CTIM-00043 User Manual

Page 17

Advertising
background image

CANpro/104 User Manual


17

www.connecttech.com

CTIM-00043 (0.01) 1/15/2010

800-426-8979 | 519-836-1291

J3B

Position

Function

Jumper Installed

Jumper Removed

1

Mem Addr[16] or I/O Addr[9] = 1

Mem Addr[16] or I/O Addr[9] = 0

2

Mem Addr[15] or I/O Addr[8] = 1

Mem Addr[15] or I/O Addr[8] = 0

3

Mem Addr[14] = 1

or

I/O Addr[7] = 1 (BasicCAN mode only)

Mem Addr[14] = 0

or

I/O Addr[7] = 0 (BasicCAN mode only)

4

Mem Addr[13] = 1

or

I/O Addr[6] = 1 (BasicCAN mode only)

Mem Addr[13] = 0

or

I/O Addr[6] = 0 (BasicCAN mode only)

5

Memory Space Enable Bit-2 [Note 1]

6

Memory Space Enable Bit-1 [Note 1]

7

Memory Space Enable Bit-0 [Note 1]

Table 21
The 3 Memory Space Enable bits select 8 choices of I/O Addresses for the Memory Enable feature.

J3C

Position

Function

Jumper Installed

Jumper Removed

1

Memory Space powers-up (or resets)

disabled

Memory Space is always enabled

2

BasicCAN mode enabled

PeliCAN mode enabled

3

CAN-1 Interrupt Shared

CAN-1 Interrupt Not Shared

4

CAN-0 Interrupt Shared

CAN-0 Interrupt Not Shared

5

Shared Interrupt(s) Pull-Down enabled

Shared Interrupt(s) Pull-Down disabled

6

Shorten Memory and I/O Bus Cycles

Normal Memory and I/O Bus Cycles

Table 22

J4 and J5

Position

Function

Jumper Installed

Jumper Removed

T

CAN Bus Termination Resistor enabled

CAN Bus Termination Resistor disabled

G

9D Connector Shell Grounded [Note 1]

9D Connector Shell NOT Grounded

Table 23
The 9D Shell is Grounded to the Isolated Ground for the respective CAN Port.