Fp2601, General safety information (continued), Installation – Campbell Hausfeld FP2601 User Manual

Page 3

Advertising
background image

3

FP2601

www.chpower.com

General Safety Information

(Continued)

18 . Do not direct paint or other sprayed

material at the compressor . Locate
compressor as far away from
the spraying area as possible to
minimize overspray accumulation on
the compressor .

19 . When spraying or cleaning with

solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer .

HOSE PRECAUTIONS
20 . Inspect hose before use .

Do not exceed working
pressure marked on hose.

Do not twist, bend

knot, or abrade

hose.

21 . Do not wrap hose around body .

Keep away from

hot surfaces and

chemicals.

Installation

LOCATION
It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than
100°F .
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow .

Do not locate the

compressor air inlet

near steam, paint spray, sandblast areas
or any other source of contamination.
This debris will damage the motor.

GROUNDING INSTRUCTIONS
1 . This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug
illustrated in Figure 1 . Make sure the
product is connected to an outlet
having the same configuration
as the plug . This product must
be grounded . In the event of an
electrical short circuit, grounding
reduces risk of electrical shock by
providing an escape wire for electric
current . This product is equipped
with a cord having a grounding
wire with an appropriate grounding
plug . Plug must be plugged into an
outlet that is properly installed and
grounded in accordance with all
local codes and ordinances .

Improper use of grounding
plug can result in a possible
risk of electrical shock!

Do not use a

grounding adapter

with this product!

2 . If repair or replacement of cord or

plug is necessary, do not connect
grounding wire to either flat blade
terminal . The wire with insulation
having an external surface that
is green (with or without yellow
stripes) is the grounding wire .

Never connect

green (or green and

yellow) wire to a live terminal.

3 . Check with a qualified electrician or

serviceman if grounding instructions
are not completely understood, or
if in doubt as to whether product is
properly grounded . Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician .

Overheating, short

circuiting and fire

damage will result from inadequate
wiring, etc.

TEST

RESET

Grounding pin

Grounded

outlet

Figure 1 - Grounding method

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air
compressor pump . When humidity is high or when a compressor is in continuous use
for an extended period of time, this moisture will collect in the tank . When using a
paint spray or sandblast gun, this water will be carried from the tank through the
hose, and out of the gun as droplets mixed with the spray material .

IMPORTANT: This condensation will cause water spots in a paint job, especially
when spraying other than water based paints . If sandblasting, it will cause the sand
to cake and clog the gun, rendering it ineffective . A filter in the air line, located as
near to the gun as possible, will help eliminate this moisture .

Advertising