P

ROBLEM

D

IAGNOSIS

O

VERVIEW

This chapter, when used in conjunction with the

System Verification

chapter, helps diagnose and

correct problems encountered in the verification process.

During some of the diagnosis procedures, we ask you to enter an administration console command.
To enter these commands, you must have an active administration session. If you need instructions
for starting an administration session, refer to

Accessing the CyberSWITCH

.

G

ENERAL

P

ROCEDURES

For the following sections, note the following:

When you are given directions to “check configuration,” you may do so using CFGEDIT or Manage
Mode. For details on these tools, refer to the

Configuration Tools

chapter.

In this chapter, if you are able to check or change information dynamically (i.e., while in Manage
Mode), we will specify this. Remember, to enter Manage Mode, issue the

manage

command at the

system prompt. Otherwise, assume that you will need to use the system’s configuration editor. To
use CFGEDIT, enter the

cfgedit

command at the system prompt. Although this utility allows you

to make changes to the configuration while the CyberSWITCH Software is still running, these
changes do not take effect until the system is rebooted.

After making an configuration changes (and rebooting if necessary), return to the system software.
The system prompt “System Name >” indicates that the system is up and running. Continue with
the verification process using the

dr

command.

LAN A

DAPTER

Problem:
The system does not display the LAN Adapter Initialization messages. Instead, the system displays
one of the following messages:

Invalid LAN Adapter identifier

LAN Adapter Command Timeout

LAN Adapter FIFO not empty, status = #

LAN Adapter LAN Controller error

LAN Adapter Response Timeout

Error opening file \system\io.bin

MAC layer Bridge did not Initialize

[IP] Initialization failure

Action:
1.

Note the displayed error message. Restart the CyberSWITCH, and recheck for one of the above
error messages.

2.

If the error message is still displayed, contact your distributor for hardware replacement.