Remote upgrade of the operational software (osw) – Cabletron Systems CSX1000 User Manual

Page 79

Advertising
background image

Workgroup Remote Access Switch 79

U

PGRADING

S

YSTEM

S

OFTWARE

Upgrading Software

5.

After the recovery, delete the file by issuing the command:

del \system\recover1

6.

Recover lost space with the command:

flash reclaim

Console Messages during SSB Upgrade:

R

EMOTE

U

PGRADE

OF

THE

O

PERATIONAL

S

OFTWARE

(OSW)

To remotely upgrade the operational software, follow these steps:

1.

From the PC/workstation, Telnet to the CyberSWITCH and login as admin.

2.

Verify that the system is ready to receive TFTP upgrades:

Enter MANAGE MODE by typing

manage

<RET> at the system prompt.

Using the MANAGE MODE command

tftp

, verify that:

TFTP feature is enabled

TFTP server is enabled

TFTP server is assigned ADMIN file access rights

Using the MANAGE MODE command

fileattr

, verify that:

ADMIN has READ/WRITE access to CONFIG files

ADMIN has READ/WRITE access to OTHER files

Exit MANAGE MODE by typing

exit

<RET>.

3.

Using the TFTP client on the remote workstation, TFTP the

UPGRADE.OSW

file to the

CyberSWITCH in binary mode. Be sure to include the file’s full pathname (for example:

D:\CSX1204\US\IPIPX\UPGRADE.OSW)

. The exact method to transfer varies, depending

upon your TFTP client.

Note:

If you experience a transmission timeout, check the retransmission setting on the TFTP
package. A retransmission rate of 10 seconds is usually sufficient; values less than that
may not work properly.

Message

Suggested Action

can’t open recover file

If you entered a filename after the flash recover
command, makes sure that the file exists on the system.
If you did not enter a filename, make sure that
\SYSTEM\RECOVER 1 exists on the system.

not enough DRAM to
create binary image

Remove DRAM-greedy activities on the system, such as
connections to other devices, compression, and
authentication. Reboot if necessary.

error in recovery file

Make sure that the recover file that you are using is
correct. Delete, Recover, and reTFTP if necessary.

Unable to remotely
recover SSB

Hardware failure in the boot device. Contact your
distributor immediately for a replacement.

successfully updated

The SSB has been successfully updated.

Advertising