PC1616/PC1832/PC1864 Installer Programming Quick Reference Chart SIA False Alarm Reduction

SIA Feature

Programming Section

Comments

Range/Default

Requirement

Exit Time
[005], 3rd entry

Access to Entry and Exit delays for each partition and Bell Time Out for the system

For Full or auto arming:
Range:45- 255 seconds
Default: 60 sec.

Required
(programmable)

Progress Annunciation/
Disable - for Silent Exit
[014], Option 6 ON

Enables audible exit beeps from the keypad for the duration of exit delay

Individual keypads
may be disabled
Default: All Enabled

Allowed

Exit Time Restart

[018], Option 7 ON

Enables the exit delay restart feature

Default: Enabled

Required

Auto Stay Arm on
Unvacated Premises
[001]-[004] Zone type 05, 06

Function Key: Stay Arming. All Stay/Away type zones (05, 06) will be automatically
bypassed

If no exit after full arm
Default: Enabled

Required

Exit Time and Progress
Annunciation/Disable
or Remote Arming
[005] and [014] bit 6

System Times and Audible Exit beeps can be disabled when using the Key fob to arm
away the system

Default: Enabled

Allowed

Entry delay(s)
[005], 1st and 2nd entry

Access to Entry and Exit delays for each partition and Bell Time Out for the system
Note: Combined Entry delay and Communications Delay (Abort Window) shall not
exceed 60s

Range: 30 sec. to 4 min.
Default: 30 sees

Required
(programmable)

Abort Window
for Non-Fire zones
[101]-[164] bit 7 ON

Access to zone attributes, i.e, swinger shutdown, transmission delay and cross zone.
Individual zones attribute bit 7 (Transmission delay) is by default ON

May be disabled
by zone or zone type
Default: Enabled

Required

Abort Window - for
Non-Fire zones
[377], 4th entry

Access to the programmable delay before communicating alarms
Note: Combined Entry delay and Communications Delay (Abort Window) shall not
exceed 60s

Range: 15 - 45 sec.
Default: 30 sees

Required
(programmable)

Abort Annunciation
[382], Option 3 ON

Enables the “Communication Cancelled" message display on all keypads

Annunciate that no
alarm was transmitted
Default: Enabled

Required

Cancel Annunciation
[328], 8th entry

Access to the reporting code for Alarm Cancelled

Annunciate that a
Cancel was transmitted
Default: Enabled

Required

Duress Feature
[*][5] Master Code
33rd and 34th entries

Do not derive code from an existing Master/User code (e.g., Master code is 1234, the
duress code should not be 1233 or 1235)

No 1+ derivative of another
user code. No duplicates with
other user codes
Default: disabled

Allowed

Cross Zoning
[018] Option 6
[101]-[164] bit 9 OFF

This option enables Cross Zoning for entire system. Individual zones can be enabled for
Cross zoning via Zone attribute bit 9 in sections [101] - [164]

Programming required
Default: Disabled

Required

Cross Zone Timer
[176]

Access to the programmable Cross Zone timer

May program
Range: 001-255 sec./min.
Default: 60 secs

Allowed

Swinger Shutdown for Alarms
[377] 1st entry

Access to the swinger shutdown limit for zone alarms

For all non-fire zones
shut down at 1 or 2 trips
Default: 1 Trip

Required
(programmable)

Swinger Shutdown Disable
[101] - [164] bit 6 ON

Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone.
Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON

For non-police
response zones
Default: Enabled

Allowed

Fire Alarm Verification
Zone type [29]

Auto Verified Fire, use only with 4 wire type detectors that can be reset by the panel 4-
wire smoke detector powered from AUX = and PGM1 - PGM4 (type 03, Sensor reset)

70 seconds reset and
confirmation time
Default: disabled

Required

Call Waiting Cancel Dial String
[304], [382], Option 4 OFF

Access to the dialing sequence used to disable call waiting

Dependant on user phone line
Default: disabled

Required

Testing

System Test:
[*][6] Master Code, Option 4

The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.

Refer to the User Manual (part no. 29007165).

Installer Walk Test Mode:
[901

This mode is used to test each zone on the system for proper functionality.

Alarm Communications
During Walk Test
[382] Option 2:

Enables Communication of zone alarms while installer Walk Test is active.

Walk Test End and Begin
Reporting Codes

[348], 1

st

and 2

nd

Entries

Access to the reporting codes for Walk Test Begin and Walk Test End.