Ventilation heights, Clearances – Dometic RM 4223 User Manual

Page 3

Advertising
background image

FIG.1a

5. VENTILATION HEIGHTS

Refer to FIG 1 & FIG. 1A., Pages 1 & 2

Installation with * Minimum Ventilation

Upper side vent Height “N”

And lower side vent

REFRIGERATOR

INCHES MM

RM 4223

Metal Side Vents

21.0

533

(2) RM 183 Vents

RM 4223

Plastic Side Vents

(1) 3107560.041

22.0

558.8

(1) 3107560.009

* These dimensions represent the minimum height

allowable. It is recommended the Upper Vent be

located to the maximum possible height of the

vehicle for optimum performance in warmer climates.

6. CLEARANCES

Minimum clearances in inches to combustible materials

are:

G:

Top

0"

K:

Side

0"

L:

Bottom

0"

M:

Rear

9/32"

N:

See NOTE

P:

See NOTE

NOTE: Clearance "M" is between the rearmost part of

the refrigerator and the wall behind the refrigerator.

NOTE: Clearance "N" is the distance between the bot-

tom of the lower vent to the top of upper side vent. For

ventilation height, refer to Section A. Installation, Item 5.

Ventilation Heights. See FIG. 2.

Surfaces directly above and sides adjacent to the

flue outlet must be of, or covered with, fireproof

material. See FIG. 2.

NOTE: Clearance "P" over top of unit condenser fins is

1/4 inch. This is the minimum height which can be allo-

wed over the condenser fins. Whenever possible, increa-

se this height by up to 11 inches; the more ventilation

you provide, the better the performance you can expect

from the refrigerator.

Fig. 2

3