ACTUAL TERMINAL LOCATION

C WALL MOUNTING INSTALLATION )

(T) Cable clamp

@ Wires for power supply

RED wire: Connect to Plus(+) wire of power

supply adaptor.

BLACK wire: Connect to Minus (—) wire of

power supply adaptor.

(

3) Hole for mounting bracket

(

4) Terminals [T] > 0 ■ Connect to door station

#1 (non-polarized)

(^Terminals QJ ,

: Connect to door station

#2 (non-polarized)

Terminals | Dj[ , [D

2[ : For communication with

door

(

7) Terminals [f] ,

, [j[] : Connect to room

station

(^Terminals [T^ , [U| : Connect to electric door

release

@ Cable clamp hole

IBG-2AD, IBG-2CD

Attach the mounting bracket to wall or gang box. Insert the prongs of the

bracket into the holes of the body and pull the body downward. Be careful not to

attach the bracket upside down.

NOTE: Locate IBG-2AD master within convenient reach of AC receptacle —

IBG-2AD power supply wires length: About 18 cm (7-1/8")

IB-DA, IB-NA, IC-RA

* Remove screws and separate back

box from front cover.

* Mount the back box (or bracket)

to wall or gang box with supplied
screws.

*

Wire two terminals and replace

front cover on the back box.

IBR-1
After wiring terminals, mount IBR-1
to wall or gang box with supplied
screws, as shown.

TERMINALS

CONNECTING WIRES

AC RECEPTACLE

POWER SUPPLY
ADAPTOR

IB-DA

IB-NA

FRONT COVER SCREW (x2)

SCREW (x2) TERMINALS

CONNECTING
WIRES

IC-RA

( WIRING )

Lay out your system in advance. Determine the exact location of each station. Make a sketch showing the number of

wires required from each station to other stations.

Refer to the chart below and select the proper wire gauge to meet your requirements.

Diameter of wire

0.5mm

0.65mm

0.8mm

24 AWG

22 AWG

20 AWG

Door station to IBG-2AD

90m

150m

230m

300'

450'

700'

IBG-2AD to IBG-2CD

45m

75m

115m

150'

230'

350'