INSTALLATION

Video monitor & power supply

MYW-P3L

MYH-CU
or MYH-CUB

18V

B1
B2

I

£

A1
A2

B1
B2

U1
U2

A

U1
U2

U1

U2

ES3

- A1

B1

- A2

B2

U1
U2

-t-

B181

Q

@ 13^

A

Do not connect + to + wire between monitors powered by different power supplies.

I^gnn ; PS-18C or PS-18E

Impedance-matching switch: Set to OFF on all monitors, except on the last monitor.

Intercom wires must not be in the same jacketed cable.

Door release

MYW-P3L

EL-9S

Door release wires must
be in separate jacketed
cables from video wires.

Auxiliary lights

MYW-P3L

MOUNTING

1. Push button on the bottom, and lift front case off

of chassis.
2. Disconnect the MYW-P3L unit from chassis.
3. Mount the chassis to wall or single-gang box.
4. Pull in cables and make wire terminations.
5. Reconnect and mount the MYW-P3L to chassis and

lock.