Wiring, Terminals block layout, Tb-m entry call system – Aiphone TB-ADM10 User Manual

Page 3: Reset switch, 4 wiring, Junction cable alignment

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

WIRING

Terminals block layout

IA22A23A24A25A26A27A28A29A2IOA2UI U

2

B

1

B

2

@ © © © © © © © © 0 ® © © ©

D C I 8V

1

A

i

2

A

i

3

A

i

4

A

i

5

A

i

6

A

i

7

A

i

8

A

i

9

A

i

10

A

i

b b N

1

N

2

H-------------------------

© © © © © © © © © © © © © © © ©

10 pairs of A1, A2

terminals for PanTilt
door stations
★ Do not cross wires with

other door stations'.

Terminal symbols

1. Door station audio, video & PanTilt signals

1A1, 1A2 (door 1) ~ 10A1, 10A2 (door 10)

2. For MYH-CU monitor

+, -

: 18V DC power supply

U1,U2

; control

B1,B2

: Video output

3. For external device

b, b : Control of Time-Lapse VCR
(to its control terminal)
Coaxial cable connector to video input on
Monitor TV
N1,N2

: unused

TB-M entry call system

TB-M is capable of connecting only one entry call adaptor, audio or video. So, it is not possible to use
TB-AD1 or TB-AD10 adaptors together with TB-ADM10 within a system.

Video monitor capacity
Only one MYH-CU video monitor can be mounted along with TB-M console.

Cable
Using cable must be a parallel cable for each door station. Do not use multi-pair cable.

Connecting TB-ADM10 to TB-M or TB-G add-on selector
TB-ADM 10 is equipped with two junction cables of 100cm long. Plug in connectors to inside sockets,
which are located on PC board of TB-M & TB-G. It decides automatically a select switch bank for door
stations.

★ When TB-ADM10 is plugged to TB-M or TB-G, the terminals of corresponding switch banks can

not be used for TB-SE subs.

Pre-tone on/off setting
Remove a cover on top left of TB-ADM 10. Do
not change A setting, which is preset for TB-M.

The second switch when put to above ON

position, validates pre-tone, which sounds at
door station (any), upon selected by TB-M.

Reset switch

When TB-ADM10 malfunctions, press Reset
switch.

TB-ADM10

Junction cable alignment

TB-20M (TB-10M) TB-40G (TB-20G) TB-ADM10

-

3

-

Advertising