Installation, Wiring, Actual ts-12k station terminal location – Aiphone TS-12K User Manual

Page 2: Installation ol terminal box )

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

* Door opener button can be used for remote control of door release. Other remote functions such as switching on outside

lights etc., can be accomplished using a proper relay.

* Excellent voice fidelity.
* Door station IB-DA, etc. can be installed with adaptor DS-B. (Up to two door stations may be connected to up to 4

masters.)

* Block paging and talkback paging is available when using PA-B adaptor.

( INSTALLATION^

Do not attempt to install your intercom system until you have read and thoroughly understood the installation pro­

cedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.

WIRING

Lay out your system in advance. Determine the exact location of each station.
We recommend a full complement of wire be installed, even though you may not initially be installing the maximum

number of stations available for your system. This way, should you decide to add a station later, you can avoid running
additional cables to existing stations. Do not connect wires to terminals CS,ED, or P3 unless appropriate equipment is used.
Speaker phone will not operate if these wires are connected parallel through system.

A maximum of 24 conductors is required for the TS-12K. A maximum of 18 conductors is required for the TS-6K.
Refer to the chart below and select the proper wire gauge to meet your requirements.

AWG WIRE SIZE

24 AWG

22 AWG

20 AWG

18 AWG

DISTANCE

550'

1 700'

775'

875'

DIAMETER OF WIRE

0.5 mm

0.65 mm

0.8 mm

1.0 mm

DISTANCE

200 m

250 m

280 m

320 m

Begin your installation with station #1. A space is provided at the left of the diagram to write in your color code.

Note the position of the C terminal at each station. Be sure you wire each station correctly.

After installing your second station we recommend that the power supply be connected to the + and ~ terminal lines at

a convenient location and that a test be made for calling and talking between each station. As each additional station is
installed retest between each station. Unplug power supply while making wiring connections.

ACTUAL TS-12K STATION TERMINAL LOCATION:

©

-

12

PI

INSTALLATION LOR"

w

ALL MOUNTINC©

1) Attach the mounting bracket to wall or single gang plaster

ring.

2) Remove the rubber feet from base of station.
3) Attach the handset cradle with supplied screws.

( INSTALLATION OL TERMINAL BOX )

(Can be mounted easily to wall or single gang box.)

1) Remove a screw and cover as shown.

2) Attach bottom case to wall or single gang box.
3) Wire terminals and replace cover.

(P3,

for connecting relative stations,

for power supply.

for talking and to be connected in common,

for receiving call and talking.

for accessory functions added to system
at later date.

for connecting door station.

for paging connection.

for door release or other remote control.

TERMINAL IDENTIFICATIONS