Air venting, Venting, Connection to a ventilation duct – ASKO 7003 User Manual

Page 11: Electrical installation

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Air

venting

There are three positions where the air
evacuation can be connected: at the rear,
on the right hand side and on the left
hand side. When the machine is supplied,
one hole at the rear is open. The other

two are covered.

The tumble dryer is supplied with a stub
pipe and a plastic band. (A flexible hose

must be supplied by consumer.)

Fit the air evacuation as follows:
• Push the hose onto the stub pipe and

fasten with the plastic

band.

Remove the cover as necessary.

• Insert the stub pipe with the hose into

the hole.

• Fit the cover to the open hole.

If you want to change the outlet;

• Remove the cover from the hole

where you wish to fit the hose.

• Fit the stub pipe with the hose

connected to it.

• Insert the stub pipe into the new

opening

• Fit the cover to the hole where the

hose was previously fitted.

Connection to a ventilation duct

Connect the exhaust hose from
the tumble dryer to a ventilation
exhaust fitting

or

to a discharge

through the wall.

Secure the hose joint to the outlet
stub on the machine.

Run the hose with as few bends
as possible to the point of dis­

charge. If necessary, it can be
extended to a maximum of 8.75
yards of 4" diameter hose.

Make any bends as gentle as

possible. A maximum of four 90°
bends may be fitted in the hose.
The more bends and the longer
the hose, the less will be the
amount of air passing through the
machine.

If more than 8.75 yards of hose is
needed, diameter must be in­

creased.

If the hose is taken to a wall
outlet, a ventilation grille
should be fitted to prevent
reverse flow of cold air.

Fit the

ventilation

grille to

the inside

or outside

of the wall

Electrical

installation

Electrical installation must be

carried out by a skilled electrician.
As supplied, the machine is

arranged for single-phase.

Connection as
delivered:

1-phase, 240 V,

heater power
2850 W, 13 A

fuse required.