Interburner, Interburner turbo reversed (tra) air flow pattern, Conventional oil burner air flow pattern – Adams Mark 10 User Manual
Page 2: Adams, Dimensions, Specifications, Lllnterbumef
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
ADAMS
INTERburner
INTERburner Turbo Reversed (TRA)
Air Flow Pattern
Conventional Oil Burner
Air Flow Pattern
Patented Turbo-Reversed-Air System or
TRA, the major breakthrough that ac
counts for INTERburner’s fuel economy.
Inside each INTERburner, TRA stabilizes
dynamic pressure while maintaining high
static pressure. It creates the most uniform
airflow at the combustion head and gives
UNEVENAin \
di
^
hi
^
utiqn
X
PAnEFlH , 1
HIOH vVusilTY^
rmw /
RESULT
An UOD^Vn How Cl ulr
wllh hl^h vticcliv con.
TIHUS:
PIMicmt I
d
Ob Lam
a
flJMciani
luaUiilr mljtiurfi a!
\ha
ccHnbuslJnii head.
precise control for the most effective
mixing of combustion air with the oil on
the combustion head ... accomplishing
efficiency levels never before achieved.
INTERburner’s flame burns hotter and
cleaner... requiring less fuel to heat
your home.
DIMENSIONS
T
4"
T
Î
SPECIFICATIONS
CAPACITIES
0.40 to 2.50G/P/H, 56,000 to 350,000 B.T.U./Hr. Input.
Other models available to 7 G/P/H.
FUEL
No. 1 or No. 2 Heating Oil.
POWER REQUIREMENTS
115 Volts, 60 Hertz, Single Phase.
MOTOR
3450 R.P.M., 1/7 H.R 115 V., NEMA “M” Flange.
IGNITION TRANSFORMER
10,000 Volts.
CONTROLS
24 Volt Primary Cad Cell Control. Intermittent or
Interrupted Ignition.
FUEL PUMP
3450 R.P.M., 100 RS.I., Singie or 2 Stage with or
without Integral Solenoid Valve.
MOUNTING
Universal Flange and Gasket. Burner Stand Kit —
Burner can be mounted in inverted position.
NOZZLE SIZE
Selection Chart on each burner cover.
Distributed by:
lllNTERbumef^
l A /
■ I ■ ! I . I I I . ■
Form IB-86
Accept only the best.
Insist on INTERburner?
INTERburner® Division • Adams Manufacturing Co., 9790 Midwest Ave., Cieveland, Ohio 44125
(216) 587-6801
Printed in U.S.A.