Product care maintenance & service, Defrosting, Cleaning – Dometic RM3962 User Manual

Page 9: Electric equipment, Caution

Advertising
background image

- 9 -

dEfRoSting

shut off the refrigerator by pressing the main power
ON/OFF button (OFF position).
Empty the refrigerator.
Leave the cabinet and freezer doors open and place
the drip tray under the finned evaporator.
Defrosting time can be reduced by filling the ice
trays with hot water and placing them in the freezer
compartment.

When all the frost has melted, dry the interior with a
clean cloth.
Replace the food. set the thermostat to the coldest
setting for a few hours. Then, reset the thermostat to
the desired setting, usually at mid setting.

1.

2.
3.

4.

5.

Fit the new heater into the pocket.
Connect the leads and refit the power module cover.
Put the insulation wool back in place.
Close the lid of the boiler.

fuses

The refrigerator is equipped with 2 fuses - one for the refrig-
erator control system (3 a) and one for the aC heater (5 a).

Replacing the fuses

To replace the fuses, follow these steps:

Tun off the refrigerator.
unplug the power cord and disconnect the
12V wires.
Remove the power module cover.
snap the fuse out of the fuse holder.
Fit the new fuse in to the fuse holder.
Put back the power module cover.

7.
8.
9.

10.

1.
2.

3.
4.
5.
6.

clEaning

always keep the refrigerator clean. Cleaning the refrigerator
is usually done after it is defrosted or put into storage. use
lukewarm weak soda solution to clean the interior liner of the
refrigerator. use warm water only to clean the finned evapora-
tor, gasket, ice tray and shelves.
NOTE! Never use strong chemicals or abrasives to clean these
parts, as the protective surfaces will be damaged. Do not spray
liquids near electrical outlets, connections or the refrigerator
components.
To keep the refrigerator operating efficiently and safely, peri-
odic inspection and cleaning of several components once or
twice a year is recommended:

Check the lower vent, upper vent and area between these
openings for any obstructions such as bird/insect nests,
spider webs, etc.
Make sure the refrigerator area is free from combustible
material, gasoline and other flammable vapors or liquids.
Clean the coils on the back of the refrigerator. use a soft
bristled brush to dust off the coils.

PRodUct caRE

maintEnancE & SERvicE

In order to keep the refrigerator working properly it is important that service is performed on a regu-
lar schedule. Please note that this service should be performed by qualified service personnel only! The
information in this section is intended for service personnel.

ElEctRic EqUiPmEnt

heater

The heat necessary for the operation of an absorption cooling
unit is supplied by an electric heater mounted in a pocket of the
boiler system. The refrigerator is equipped with one electrical
heater for 120 V aC.

Replacing the heater

To replace the heater, follow these steps:

Turn off the refrigerator. unplug the power cord and
disconnect the 12V DC power.
Remove the power module cover.
Disconnect the heater leads.
With a pair of pliers, unfold the lug holding the lid of
the boiler casing and then, open the lid.
Remove some insulation wool for the heater to be
accessible.
Turn and lift the heater out of its pocket.

1.

2.
3.
4.

5.

6.

Do not use:

A knife or an ice pick, or other sharp tools to
remove frost from the freezer shelves. It can
create a leak in the ammonia system.
A hot air blower. Permanent damage could result
from warping the metal or plastic parts.

CAUTION

CAUTION

If your refrigerator stops cooling, immediately turn the refrigerator off and see a Dometic dealer.

Advertising