® AlPHONE

832564 0187 ®

TWO STATION INTERCOM

MODEL: LAM-1 S (SET)

SIMPLE "DO IT YOURSELF" INSTALLATION - EASY TO OPERATE!

Loudspeaking type intercom with volume control.
Open voice sub station allows hands free remote reply from
anywhere in a room.
Designed for either desk top use or wall mounting (Hardware
included).
Electronic tone call signal.
Power source: PS-6D or four 1.5V “C” (SUM-2) batteries.

Wiring and communication range: Single pair of wires.

Select the proper wire gauge to meet your requirements from

the chart below;

DIAMETER OF WIRE

0.5mm

0.65mm

0.8mm : 1.0mm

DISTANCE

120m

200m

300m 1 480m

1

AWG WIRE SIZE

24 AWG

2 2 AWG

20AWG ! 18AWG

DISTANCE

400'

650'

1,000' 1,600'

LA-A SUB

OPERATION

MASTER STATION:

1. Depress ‘TALK’ switch during transmission.

2. Release ‘TALK’ switch to listen to or monitor sub station.
3. To conserve batteries, depress ‘OFF’ switch when not using

system.

4. You may call sub station by voice or by call tone.

To call by voice, depress ‘TALK’ switch and start speaking.
To call by call tone, depress ‘TALK’ and ‘OFF’ switches
simultaneously.

5. Adjust volume control for desired volume level.

SUB STATION:

1. To call master station, momentarily depress ‘CALL’ switch.

2. Talk and listen hands free to master. Do not push ‘CALL’

switch during conversation.

INSTALLATION

1. Insert four 1.5 V “C” (SUM-2) batteries (not included) in

battery compartment. + and — positioning of battery termi­
nals are clearly indicated in the battery compartment.

2. Connect terminals #1, E on LAM-1 master with two wires

to #1, E on LA-A sub. Nonpolar unit allows connection of
either wire to either terminal on sub station.

SPEAKER/MICROPHONE

LAM-1

SPEAKER/MICROPHONE

OFF SWITCH

TALK SWITCH

LAM-1 BACK VIEW

^ ' €.

[la a

U

W !

]|

BATTERY COVER

BATTERY COMPARTMENT

TERMINAL BLOCK

VOLUME CONTROL

FOR CALL TONE

(Use minus driver)

LA-A

LAM-1

PS-6D
Power supply

XT

DC .6V

*Power supply is not required if master

is powered by batteries.

+ 0'

-0

10

E0

DO NOT REMOVE JUMPER,
OTHERWISE SUB STATION
WILL NOT BE ABLE TO
CALL MASTER STATION.