Syntax:

i32 setRemoteSwitch(u8 val)

Description:

The function sets the status of the Remote Switch.

Parameters:

This function takes an unsigned char as the parameter.

The value of this parameter can be ‘ENABLED’ (0x5A) or

‘DISABLED’(0xA5).

Return Value:

If this function works successfully, it returns 0, any other

value standards for error.

Syntax:

i32 getBattValt(float *vol)

Description:

This function gets the battery voltage ant put it in the

memory which is pointed at by the pointer ‘vol’.

Parameters:

This function takes a pointer to a ‘float’ variable as the

parameter. The reading of the battery voltage is put at the

memory which is pointed at by the parameter ‘vol’.

Return Value:

If this function works successfully, it returns 0, any other

value standards for error.

Syntax:

i32 getBattMonitor(u8 *val)

Description:

The function gets the status of the Battery Monitor.

Parameters:

This function takes a pointer to an unsigned char variable

as the parameter. After calling this function, the status

of the Battery Monitor will be put at the memory which is

pointed by the parameter ‘val’. If the Battery Monitor is

enabled, ‘*val’ is 0x5A. If the Battery Monitor is disabled,

the ‘*val’ is 0xA5. Users can use the macros ‘ENABLED’

(0x5A) and ‘DISABLED’(0xA5) to test the status value

‘*val’.

Return Value:

If this function works successfully, it returns 0, any other

value standards for error.

Syntax:

i32 setBattMonitor(u8 val)

Description:

The function sets the status of the Battery Monitor.

Parameters:

This function takes an unsigned char as the parameter.

The value of this parameter can be ‘ENABLED’ (0x5A) or

‘DISABLED’(0xA5).

Return Value:

If this function works successfully, it returns 0, any other

value standards for error.