Ventilation – Dometic hipro 6000 User Manual

Page 11

Advertising
background image

Min. 31 in

2

(200 in

2

)

If you are considering integrating a Dometic

refreshment center into the furniture, don’t forget that

the cooling unit needs fresh air! These sketches show

various ways to integrate and ventilate a unit.The

open cross-section for fresh air supply and extracted

air must be at least 31 square inches (200 cm

2

), and

the air flow around the cooling unit should be

unrestricted. If you have any questions, Dometic’s

experts will be happy to answer them.

Ventilation

11

Sufficient ventilation can be accomplished

even in taller furniture. For proper cooling, the

air needs to flow freely around the cooling unit

and exit freely at the top.

The opening for supply air can also be built

into the furniture base, but the footprint must

not prevent the air from passing the cooling

unit freely.

Should you want to place the unit on the

floor panel of your furniture, be sure to use the

optional 1-5/8” (42 mm) feet.These and an air

grille integrated in the furniture door ensure

sufficient ventilation. Both doors can be

connected with a slide hinge which

compensates for the different pivot points.