Acrosser AR-B9622 User Manual

Page 26

Advertising
background image

AR-B9622 User’s Guide

3-8

3.2.9 Serial Port

(1) Full RS-232 Signal / Power Select for COM-A (P3)

P3 select the full RS-232 signal or power select for CN10--COM A, if user chooses the power supported then the
COM A’s RTS will be instead of the +12VDC signal; and the CN10--COM A’s CTS will be instead of the +5VDC
signal.

P3

Power Supported
by +5VDC

Full RS-232 Signals

(Factory Preset)

1

2

1

2

6

4

3

5

6

4

5

3

Figure 3-13 P3: Full RS-232 Signal / Power Select for COM-A

(2) RS-232/RS-485 Select for COM-D (JP6)

JP6 selects the on-board RS-232/RS-485 for CN10 – COM D.

A

B

C

JP6

1

3

2

RS-232

Factory Preset

A

B

C

JP6

1

3

2

RS-485

Figure 3-14 JP6: RS-232/RS-485 Select for COM-D

(3) RS-485 Terminator Select (JP4)

2

OFF

Factory Preset

JP4

1

1

2

ON

Figure 3-15 JP4: RS-485 Terminator Select

(4) RS-232 and Digital I/O Signal Output Select for COM D (JP3)

2

RS-232 Signal

Factory Preset

JP3

1

3

2

1

3

Digital I/O Signal

Figure 3-16 JP3: RS-232 and Digital I/O Signal Output Select for COM-D

(5) Digital I/O Signal Output Header for COM D (J6)

2 DSR

J6

1 DTR

3 Ground

Figure 3-17 J6: Digital I/O Signal Output Header for COM D

Advertising