4 serial ports (com1, com2), Rs-232, Rs-485 – Acrosser AR-B1640 User Manual

Page 11

Advertising
background image

AR-B1640 User’s Guide

11


3.4 SERIAL PORTS (COM1, COM2)

COM1 D-SUB 9-PIN



COM2 10-pin Connector

1

10 2

9


3.5 COM1 RS-232/RS-485 SELECT (XP1, XP2)















RS-485 Terminator Select (J2)

J2 (ON)


RS-485 Header (J1)

1

2

3

PIN

Signal

PIN

Signal

1

/DCD1

2

RXD1

3

TXD1

4

/DTR1

5

GND

6

/DSR1

7

/RTS1

8

/CTS1

9

/RI1

10

GND

PIN

Signal

PIN

Signal

1

/DCD2

2

/DSR2

3

RXD2

4

/RTS2

5

TXD2

6

/CTS2

7

/DTR2

8

/RI2

9

GND

10

NC

JUMPER

FUNCTION

XP1

1

3

5

1

2

3

XP2

RS-232


FACTORY PRESET

XP1

1

3

5

1

2

3

XP2

RS-485

PIN

Signal

1

N485+

2

N485-

3

GND

1

5

6 9

FACTORY PRESET

* When there is only one line the setting should be left off
(please take off the jumper), if multiple blocks are used on a
single line this should be set to “ON”(place a jumper) in order
to properly terminate the connection for better transmission

Advertising