Acquisition time, Dynamic conditions, Power – Acrosser AR-V5430FLAT User Manual

Page 32: Interface, Environmental

Advertising
background image

AR-V5430FL Installation Guide

Acquisition Time

Reacquisition

0.1 sec., average

Hot start

1 sec., average

Warm start

38 sec., average

Cold start

42 sec., average


Dynamic Conditions

Altitude

18,000 meters (60,000 feet) max

Velocity

515 meters/second (1000 knots) max

Acceleration

Less than 4g

Jerk

20m/sec **3


Power

Main power input

3.8V ~ 6.5V DC input

Power
consumption

60mA (Continuous mode)
40mA (Trickle power mode)


Interface

Baud rate

4,800 to 57,600 bps adjustable

Output message

SiRF binary or
NMEA 0183 GGA, GSA, GSV, RMC, VTG, GLL


Environmental

Operating Temp

-40°C to +85°C

32/39