1 operating mode – Dolby Laboratories DP572 User Manual

Page 55

Advertising
background image

Dolby E Multichannel Distribution System User Manual

DP572 Dolby E Decoder

4-7

4.2.1

Operating Mode

Figure 4-4 Operating Mode menu

Program Play
Enable
: Allows the input to Main In to vary from the nominal 48 kHz sample rate.

Permits the decoder to operate with a VTR in Program Play mode. As the
sample rate varies from 48 kHz, the decoding latency is no longer exactly
one video frame. The P in the display below reflects that Program Play is
enabled.

Disable: The sample rate of the Main In input must be 48 kHz for the DP572 to decode.

48 kHz Pull Down
See 48kHz Pull Down on page 3-10.

PCM Bypass
Enable
: Allows smooth transitions between decoded Dolby E and PCM audio.

Disable: Audio outputs are muted until a valid Dolby E stream is received at the

Main In input. This is useful when editing on a VTR while decoding with
the DP572.

Bypass Metadata
This feature is only relevant if PCM Bypass mode is enabled.

Disable: While the DP572 receives PCM input, no metadata is output.

Enable:

While the DP572 receives PCM input, a default set of metadata parameters
more appropriate for two-channel audio is sent instead of the Dolby E
stream’s metadata.

DP572 Unit Setup

Operating Mode

Operating Mode

PCM Bypass

Operating Mode

48kHz Pull Down

Program Play

Disable

48kHz Pull Down

Disable

PCM Bypass

Disable

Program Play

Enable

48kHz Pull Down

Enable

PCM

Enable

Bypass

Operating Mode

Program Play

Enter

Enter

Enter

Enter

Esc

Esc

Esc

Esc

Operating Mode

Latency

Bypass

Bypass Latency

1 Frame

Bypass Latency

Minimal

Enter

Esc

Operating Mode

Bypass Metadata

Bypass Metadata

Disable

Bypass Metadata

Enable

Enter

Esc

Dolby E

P

5.1 + 2

20bit

Advertising