RP124 Installation Instructions

P/D 092702

ADVANCED CONTROL TECHNOLOGIES, INC.
Indianapolis, Indiana 46278

BEFORE YOU BEGIN...

READ ALL INSTRUCTIONS

Make sure your installation will conform to all applicable codes and requirements.

TEST FOR SIGNAL STRENGTH AND NOISE...

using appropriate test equipment. It is necessary to test the installation in the actual operating
environment. The amount and types of line loads may reduce the strength of the transmitted signal
and/or electrical noise may cause interference with the transmitted signal. Proper installation may
require additional couplers, filters or repeaters. Special coupling devices are required to allow signal
to be distributed to all phases and zero-crossings in multi-phase and multi-transformer distributions.

IF YOU HAVE ANY QUESTIONS...

consult your nearest Engineered System Center (ESC) for additional information.

There are no field repairable assemblies on this unit. It is covered by a two year limited warranty. If
service is needed, the unit must be returned to the ESC where purchased. Contact your ESC for return
details.

INSTALLATION / SETTING THE ADDRESS

WITH A LOAD CONNECTED: (See page 2 for "without a load connected")

1. Make sure the load connected does not exceed the device rating.

2. Plug lamp or load (make sure it is turned ON) into RP124 outlet.

Note: If you first plug the RP124 into an outlet it will respond only to factory preset address A1.

3. To change the address, hold in the push-button on the front of the module, insert the RP124

into the receptacle, or apply power if connected to a controlled circuit. If there is a lamp connected
to the module, the lamp will be illuminated, turn OFF, and then turn back ON (make sure the lamp
is turned on before you start). YOU DO NOT NEED A LAMP TO BE PLUGGED INTO THE
MODULE TO CHANGE THE ADDRESS BUT IT IS HELPFUL.

NOTE: The module waits for a new address to be configured for up to 1 minute. If a new address is
not received within that time, the module will turn off the lamp (if there is one plugged in and turned
to ON), and continue to respond to the old address.

4. Now transmit the desired address twice with a 1 second pause between transmissions (can be

any single address from A1 to P16) or address plus command (can be ON or OFF). Load does
not respond to configuration command as such, but the lamp will turn OFF indicating the new
address is now configured.

5. The module will now respond to the new address. Transmit an ON command to verify.

RP124

A10 120 VAC, 15A, Plug-in Relay Receiver,

Push-Button functions

1. To configure address
2. Local ON and OFF (push and release)

Plug Load in here

Three prong plug to
120 VAC Outlet