Thank you for purchasing an Amaircare® portable air filtration system.

With proper care and maintenance, your Amaircare® system will provide

many years of reliable service, improving the quality of your air.

INSTALLATION

1. Place the unit in the area where you want the cleanest air.

2. Plug the unit into a live grounded outlet. The cord has either a 110V

plug for 110 volt operation or a 220V plug for 220 volt operation

depending on the area in which the unit was sold.

3. Turn the unit on by rotating the control dial clockwise until you hear or

feel it click. The unit will start on the “LOW” position. To increase the air

flow continue to rotate the control dial clockwise.

4. To turn the unit off, rotate the control dial counter-clockwise until you

hear of feel it click into the “OFF” position

CAUTION

1. Make sure the cord is not in the path of people walking or where

anything can be rolled over it.

2. Do not place any objects on top of the unit or allow anyone to sit on it.

3. NEVER place any liquids or plants on the unit. Moisture could leak into

the unit and damage the filter media or electrical components.

4. The air filtration system discharges the cleaned air through the vent

at the bottom rear of the unit. On “HIGH” the velocity of the

air coming out is high to enhance circulation throughout the area

being cleaned. If the airflow is bothersome or creates a draft, turn the

unit until the air is directed toward an unoccupied area of the room.

NOTE: You may notice a slight “new” smell from the unit when your first

turn it on. This is normal and harmless and will dissipate within a few days.

Removing the Filter Assembly

1. Turn the switch to the ‘off’ position

and unplug the power cord from outlet.

2. Place the unit on a soft surface

3. This step requires a friend’s assistance

Have someone hold the motor assembly

stationary while you twist the filter

assembly counter-clockwise to release it,

then lift to remove.

4. Remove the foam ‘0’-ring and put it in

a place where it will not be damaged or

lost. It will be needed during re-assembly.

Replacing the Foam Pre-Filter

1. Place the filter assembly upside down

on a soft surface

2. Gently pull the foam pre-filter upwards

to remove it from the assembly.

3. To replace with a new or washed*

pre-filter, carefully spread the foam filter

around the outer edges of the filter

assembly and gently pull it down to it’s

original position (covering the exposed

steel mesh)

* In order to increase filter life, foam pre-

filters may be hand washed, allowed to

dry, and re-used. Over time and

increased washings the filter will eventu-

ally need to be replaced.

Replacing the Inner Blanket

Caution: When completing the follow-

ing steps, please use extreme care not

to inflict pressure on the underlying HEPA

filter when replacing the Inner Blanket

1. Look inside the Filter Assembly to

locate an end of the Inner Blanket.

2. Without applying pressure directly on

the HEPA filter located behind the Inner

Blanket, fold the ends of the old Inner

Blanket in and remove it from the unit.

3. Insert the new Inner Blanket inside the

HEPA Cartridge with the edges over-

lapped by at least one inch. Once it is

in position gently spread the Inner Blan-

ket against the HEPA filter until the two

ends of the blanket meet.

Hepa Cartridge Replacement

1. Remove and carefully discard the old

HEPA Cartridge. (Filter Assembly)

2. Install the new HEPA Cartridge. (Filter

Assembly) see: ‘Re-Assembling the Unit’

Re-Assembling the Unit

1. Gently place the motor assembly on

a soft surface

2. Place the foam ‘O’-ring onto the

Motor Assembly (if a new foam ‘O’-ring

is available, use it in place of the old

one)

3. This step requires a friend’s assistance

While a friend support the Motor Assem-

bly, place the Filter Assembly on top of

the Motor Assembly and firmly twist the

Filter Assembly clockwise until both

assemblies are locked together.

Your unit is now ready for use.

FILTER REPLACEMENT INSTRUCTIONS

*Caution - Never lift the unit by the filter assembly, allways lift from the motor assembly

THREE-STAGE FILTRATION

STAGE 1: Foam Prefilter

Removes large particulates and

odors. Extends the life of the HEPA

filter.

STAGE 2: HEPA filter

99.97% efficient @ 0.3 microns.

Removes dust, pollen, bacteria,

animal dander, attached viruses,

cigarette smoke, radon daughters

and more.

STAGE 3: V.O.C. filter

Removes odors and hazardous

chemicals that may off-gas from

cleaners, paints, solvents, carpets,

furniture and other items contain-

ing synthetic materials.