Mf3542 exhaust blower

Advertising
background image

F:\AESBusinessSystems\AES Technical\Piece part instructions\MF3542 Exhaust Blower.doc

MF3542 Exhaust Blower

All Magnum pellet units















• Turn off power on control panel and unplug from the power supply.

• Disconnect the exhaust blower leads from the wire harness make sure when pulling off

wires that you use pliers by the end of the terminals, so you don’t pull out the wire from
the ends.

• Remove existing exhaust blower.

• Remove existing exhaust tube from the

exhaust blower being replaced.(save the
#8-tek screws for later use)

• Clean the rectangle outlet of the exhaust

tube of any old high temp silicone.






• Place a 1/8” bead of high temp silicone on the rectangle outside edge of the exhaust tube.








• Slip rectangle end of the exhaust tube over the rectangle outlet of the new exhaust

blower. Push tight until the exhaust tube hits the flange of the exhaust blower housing.
Making sure the tube alignment to blower is straight.