American Energy Systems MF3553 Auger Inspection User Manual

Auger inspection part #mf3553

Advertising
background image

F:\AESBusinessSystems\AES Technical\Piece part instructions\MF3553 Auger Inspection.doc

Auger Inspection

Part #MF3553

(inspection of Countryside augers )



• Verify auger free of gouges, nicks, scratches and dents fix if possible.

• Verify auger free of rust and excess oil, if necessary use wire brush to clean and then wipe auger down

with paint thinner to remove all oil. Then lightly oil.




• Verify auger

flighting pitch
dimension from
right to left can not
decrease. It may
increase within
tolerance
progressively but
not decrease.



• Verify all burrs and sharp edges have been removed.

• Inspect all welds they must be neat, smooth and good penetration from flighting to shaft.


• Using bench grinder

remove a 1/16”
from both ends
approx. 2” in as
shown.


• Verify outside diameter of flighting is uniform and fit

correctly in auger tube as shown. Using a flashlight
position behind auger and spin the auger making sure
flighting is uniform.

Advertising