Wire Harness Assemble DC

Part #RP2062

for Models Baby DC, Win DC, Essex DC & T40 DC
















• Unplug unit

• Open both side panels.

• Remove existing wire harness.

• Attach the following:

o

Control Board

molex connector (6 prong and 8 prong)

o

Exhaust

Fan

blue

wire

to

red

lead purple wire to blue lead

(depending on style fan white to blue wire black to purple wire)

o

High Limit Snap Disk

two orange wires to both leads

o

Vacuum Pressure Switch

two grey wires to both leads










o

Proof of Fire Snap Disk

two brown wires to both leads

o

Auger Motor

yellow wire to top terminal w/ red dot (+) yellow/black wire to

bottom

terminal

(-)

o

Room Air Fan

pink wire to red lead one purple double to black lead

o

Electrical

Plug

molex

connector

to

power

supply

(5

prong)

o

Igniter

red/white

wire

to

one lead white wire to one lead

ƒ

(these are not plugged into anything if there is not an igniter)


N.O.

3

N.C.

2

COM

1

Attach one grey wire to ‘Com

1’ and one grey wire to ‘NO 3’.

Attached hose to back

connection ‘L’.

RT080 World Magnetics
Vacuum Pressure Switch

Attach one grey wire to ‘Com 1’

and one grey wire to ‘NO 3’.

Attached hose to bottom connection

‘P2’.

RT080 Clark Controls

Vacuum Pressure Switch

N.O.

3

N.O.

2

N.O.

1