Room Fan Blower Assembly Complete

#CF25

For 6500 & 7500 furnance

• CF31 Blower Housing w/ mounting feet

• CF32 Blower Capacitor

• CF33 Blower motor


Wire connections:

• Red wire for low output (not used)

• Yellow wire high output

• Black common



• Remove all parts from boxes.

• Mount the mounting bracket to the blower motor see instruction. Make sure that all 3 legs of bracket are

equal and the there is amount 2 holes shown.














• Add a male connector to the black and

yellow lead from the blower motor.
Connect the capacitor to the blow leads in
position shown.













CF32 Blower capacitor

CF31 blower housing w/ hardware

2 holes shown