American Energy Systems P6115 Wire Harness User Manual

Wire harness assembly part #p6115

Advertising
background image

F:\AESBusinessSystems\AES Technical\Piece part instructions\P6115 Wire Harness Assembly 6500.doc

Wire Harness Assembly

Part #P6115

For Models 6500 units







• Unplug unit

• Open both side panels.

• Remove existing wire harness.

• Attach the following:

o

Control Board

molex connector

o

Auger Motor

black wire to Vacuum Pressure switch (Com) grey wire to one lead

o

Electrical Plug

double white wire to inside terminal (top, right side) Black/orange
wire to outside terminal (top, left side) green wire to bottom

terminal other end of green wire screwed to base of unit

o

Vacuum Pressure Switch

grey wire to left terminal black wire to middle terminal if Clark

grey wire to left terminal black wire to right terminal of World Magnetic


















o

Room Fan Sensor

double white wire to

bottom terminal green wire to top terminal

o

High Limit Sensor

blue wire to bottom terminal double grey to top terminal

o

Room Air Fan

white wire to red wire grey wire to double black wire

o

Exhaust Fan

black wire to white wire red wire to black wire

N.O.

N.C.

COM

Attach one grey wire to ‘Com ’

and one grey wire to ‘NO’.

Attached hose to back

connection ‘L’.

RT080 World Magnetics
Vacuum Pressure Switch

Attach one grey wire to ‘Com 1’

and one grey wire to ‘NO 3’.

Attached hose to bottom connection

‘P2’.

N.O.

1

N.O.

2

N.O.

3

RT080 Clark Controls

Vacuum Pressure Switch

N.O.

1

N.O.

2

N.O.

3

looking in from side w/o
control panel

Advertising