American Energy Systems PP-1030-LR Wire Harness User Manual

Wire harness assembly part #pp-1030-lr

Advertising
background image

F:\AESBusinessSystems\AES Technical\Piece part instructions\PP-1030-LR Wire Harness Assembly LR01.doc

Wire Harness Assembly

Part #PP-1030-LR

For Models LR-01 (prior to 2011)














• Unplug unit.

• Open both side panels.

• Remove existing wire harness.

• Attach the following:

o

Control Board

molex connector

o

Exhaust Fan

gray/white & black molex to black leads

o

Auger

Motor

brown/white & black to black leads

o

Room Air Fan

blue/white & black molex to black leads

o

Vacuum Pressure Switch

green lead to top terminal violet lead to bottom terminal

o

High Limit Snap Disk

gray lead to top terminal violet to bottom terminal

ƒ

all white snap disk

o

Snap disc right side

yellow wire to top terminal violet wire to bottom terminal

ƒ

yellow & white snap disk

o

Proof of Fire Snap Disk

brown wire to top terminal violet wire to bottom terminal

o

located by exhaust motor yellow & white snap disk

o

Electrical Plug

double white wires middle terminal black wire bottom terminal
green wire to top terminal other end of green wire screwed to base
of unit

o

Igniter

red

wire

to

one

lead white wire to one lead

o

thermostat

blue lead and red lead (these are not used if NO thermostat)

• Plug unit in

• Turn on unit







Advertising