background image

Auger Weldment Assemble

Part #PP-1502

used on LR01












• Turn power off unit and unplug from wall.

• Remove auger motor access panel using

1/8” allen wrench located on the back of
the unit.











• With access panel removed using a 1/8” allen wrench remove the 2 – allen screws holding the

complete auger assemble as soon in figure #1.

• Make sure you keep the spacer and the male drive assembly. They will be used when you

replace the auger PP-1502.

• Prior to installing a new auger motor inspect the auger tube to insure no deep scratch or

gouges are in the walls of the tubing.

• Inspect the auger bushing located in the top auger housing weldment replace if damaged CF-

114 auger bushing.

• Carefully insert the auger weldment into the tube as shown.

• Install the spacer and male drive assembly so that the pins on the male drive assembly line up

with the slots on the auger weldment.

• Line up the hole for auger weldment to the holes on the auger housing. Insert the 2-1/4-20 x

½” screws into holes and tighten. Make sure the auger motor is equally spacered from top to
bottom.





access panel

¼-20 x ¾” AH Cap