American Energy Systems Ovation User Manual

Page 24

Advertising
background image

Version 7.1

24

GASKET REPLACEMENT
Remove the doors from the unit. Place the doors, face down on a protective surface to ensure no
marring or scratching occurs during gasket replacement. To replace the Thermoglass

™ knitted rope

and tape gasket, first remove all of the old material and gasket cement. Use a putty knife or other
sharp instrument to assist in removal. Use caution to prevent injury when removing old material. It
is important to ensure the doorframe area is totally clean before installing the new gasket cement
and material. The gasket must fit tight against the doorframe in order to ensure a proper airtight
seal when the stove is being operated. Apply gasket cement to the gasket channel per instructions
provided with the gasket kit. Once the cement has been properly applied, install the new gasket.
Both gasket and gasket cement are available from your authorized Country Flame dealer. The
following table defines the gasket material used in the Ovation stove:

Gasket

Length Quantity Dimensions

Around glass

4.25 feet each

2

¾” wide by 1/16” thick tape

Doorframe

5 feet each

2

3/8

” rope, high density

Ash drawer

30 inches

1

½” wide by 1/8” thick tape


CLEARANCES
Table 1 is used to determine clearances for the stove installation based on whether a single or
double-wall connector is used from the appliance to the chimney.

SINGLE-WALL PIPE

DOUBLE-WALL

PIPE*

DISTANCES

OV-1700 & 2100

OV-2600

OV-3000

ALL MODELS

A. SIDEWALL TO UNIT

19” 20” 22” 14”

B. BACK WALL TO UNIT

10” 12” 12” 5”

C. CORNER TO UNIT

6” 6” 8” 2”

D. SIDEWALL TO CONNECTOR

28” 29” 31” 23”

E. BACK WALL TO CONNECTOR

13” 16.5” 16.5” 9”

F. CORNER TO CONNECTOR

16” 16.5” 19” 11.5”

TABLE 1: REQUIRED CLEARANCES


* Factory-built chimney systems should use a chimney UL Listed to 103HT or equivalent product
in the United States. For Canada, use chimney listed to ULCS629.

FIGURE 9: FREESTANDING CLEARANCE REQUIREMENTS

Advertising