TROUBLESHOOTING

TAKING CARE OF YOUR RECHARGEABLE BATTERIES

• Ensure that you fully charge your batteries for 15 hours before their first use.
• To maintain maximum battery life it is recommended that you fully discharge your

batteries periodically. Battery performance can be diminished by leaving the batteries
constantly charging. If your parent unit is not in use, please turn it off.

• Inadequate battery power can impair the performance of your monitor. If you are

not happy with the performance of your parent Unit/Monitor please replace the
rechargeable batteries (4 or 8 x NiMH Rechargeable Batteries).

• It is advisable to change the batteries every 6 months.

LOSS OF CONNECTIVITY

• In the case of loss of connectivity, the first step is to bring the parent Unit and

Nursery Unit closer together and make sure that both units are ON to restore
the connection. If there is still no connection and no out of range warning after the
above has been done, then and only then should the re-connection procedure below
be done.

1) Turn the Nursery Unit and the parent Unit

Off.

2) Turn ON the parent unit - press and hold

the MENU button. The Out of Range
alarm will flash and you will hear a beep.

3) Turn ON the Nursery Unit and - press and

hold the top button to reconnect. The TIc
light will flash within a few seconds and
you will hear a confirmation beep.

4) You will know your reconnection was

successful when c1 appears on the parent
Unit display, then normal screen will
appear.

NOTE:

The connection process should be done

within 30 seconds, if you ignore or it takes

longer then you will need to restart the

steps.

FALSE ALARMS

• Turn Off the Nursery Unit.
• Verify the connection between Sensor pad and Nursery Unit. Unplug and reconnect

the cord.

• Make sure there is no bedding between mattress and Sensor pad.
• If the crib has a spring or slat base, place a hardboard between the crib base and the

Sensor pad measuring at least 33 cm x 33 cm and 6 mm thick.

• Make sure Sensor pad is positioned as described under the setup requirements.

Sensitivity may need to be adjusted, refer to step 5.3.

3

4

1

2

STEP 6 - ACTIVATING AND DEACTIVATING ADDITIONAL FUNCTIONS

The Angelcare

®

monitor can be used with the pre-program factory settings

or you can also customise your settings to your preference.

IMPORTANT
When in MENU or SUB-MENU mode NO
sound, alarm or vibration will be emitted
from either the parent Unit or the Nursery
Unit even if they were activated before
pressing the MENU or SUB-MENU mode.

In order to activate any
changes made in the main
MENU and SUB-MENU
it must be confirmed by
pressing the

Select button.

Slide

right ‘wing’ of Nursery Unit

to turn night light

ON or OFF.

6.2 - NIGHT LIGHT

6.1 - PAGER

Allows you to locate the parent Unit.

TO LOCATE THE PARENT UNIT:

press Nursery Unit

Pager button. The

parent Unit will emit a paging sound.

TO STOP THE PAGING SOUND:

press the power button on the
parent Unit. After 1 minute the
sound will stop automatically.