Technologies inc, Typical wiring diagrams, Please visit our website for other products – AZEL i-Link SERIES ZONE VALVE CONTROLS FOR HYDRONIC / RADIANT FLOOR HEATING SYSTEMS User Manual

Page 3: Set dip switch jumper3&4 to on, Zone 1 n l 120 vac, Wiring for prioritizing dhw circulator

Advertising
background image

TYPICAL WIRING DIAGRAMS

Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4 1 2 3 4

MASTER SLAVE

ON

ZONE 1 PRIORITY

OFF

TIMER

Do Not Use

* Set DIP Switch
Jumper3&4 to ON

POWER

PRIORITY

ZONE VALVES

T2

T3

T4

T5

T6

T1

Z1

Z2

Z3

Z4

Z5

Z6

N L

CIRC

NC COM NO

Zone 1

N L
120 VAC

FUSE 2.5

AMP

MAX

XX Delay Timer

ON

OFF

ON

JUMPER 3&4

1 2 3 4 5 6

TYPICAL APPLICATION OF TWO SZ-V6 CONTROLS CONNECTED TOGETHER

P.O. Box 53138

10 Royal Orchard Blvd.

Thornhill, Ontario, Canada L3T 7R9

Ph: 905-223-5567 Fax: 905-223-3778

Email: [email protected]

www.azeltec.com

A

ZEL

TECHNOLOGIES INC.

Please visit our website for other products

ZONE EXPANSION

T1 T1 T2 T2 T3 T3 T4 T4 T5 T5 T6 T6

1 2 3

R W R W R W R W R W R W

24VAC OUT

R

C

X1 X1

ZONE 1


END

SWITCH


X X

THERMOSTATS

THERMOSTAT

(eg. Azel D-135EB)

N L
120 VAC

L N
CIRC

NC COM NO

Zone 1

DHW CIRCULATOR

ZONE CIRCULATOR

WIRING FOR PRIORITIZING

DHW CIRCULATOR

SET TO MASTER

Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4 1 2 3 4

MASTER SLAVE

ON

ZONE 1 PRIORITY

OFF

TIMER

Do Not Use

* Set DIP Switch
Jumper3&4 to ON

POWER

PRIORITY

ZONE VALVES

T2

T3

T4

T5

T6

T1

Z1

Z2

Z3

Z4

Z5

Z6

N L

CIRC

NC COM NO

Zone 1

N L
120 VAC

FUSE 2.5

AMP

MAX

XX Delay Timer

ON

OFF

ON

JUMPER 3&4

1 2 3 4 5 6

ZONE EXPANSION

T1 T1 T2 T2 T3 T3 T4 T4 T5 T5 T6 T6

1 2 3

R W R W R W R W R W R W

24VAC OUT

R

C

X1 X1

ZONE 1

END


SWITCH


X X

THERMOSTATS

SET TO SLAVE

Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4 1 2 3 4

MASTER SLAVE

ON

ZONE 1 PRIORITY

OFF

TIMER

POWER

PRIORITY

ZONE VALVES

T2

T3

T4

T5

T6

T1

Z1

Z2

Z3

Z4

Z5

Z6

N L

CIRC

NC COM NO

Zone 1

N L
120 VAC

FUSE 2.5

AMP

MAX

XX Delay Timer

ON

OFF

ON

JUMPER 3&4

1 2 3 4 5 6

ZONE EXPANSION

T1 T1 T2 T2 T3 T3 T4 T4 T5 T5 T6 T6

1 2 3

R W R W R W R W R W R W

24VAC OUT

R

C

X1 X1

ZONE 1

END


SWITCH


X X

THERMOSTATS

THERMOSTAT

THERMOSTAT

THERMOSTATS

Boiler/
Burner
Control

T

T

TT on Boiler with

DHW TT Terminals

Boiler
Control

T

T

DHW

Boiler/
Burner
Control

T

T

TT on Boiler with

DHW TT Terminals

Boiler
Control

T

T

DHW

N

N

L

L