Manual Comfort Control

Control Installation & Setup

PNE2002 Series Control

Page 7

Control Installation & Setup

Problem Solving

THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.

FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER

TO THE END OF THESE INSTRUCTIONS

PROBLEM

PROBABLE CAUSE

REMEDY

a Black – out

a

Wait

b Tripped Circuit Breaker

b

Reset

c Blown Fuse

c

Replace

Unit fails to
start

d Electrical Fault

d

Call Climate Technologies Service Provider

a Pump Seized

a

Isolate power and then take off top of pump
and try to free it. Some lubricant may help.

Pump fails
to start

b Pump Burnt Out

b

Call Climate Technologies Service Provider

a Float Valve Leaking

a

Check adjustment or replace seal

Water
leaking
from
overflow

b Drain from Celdek Pads

b

Normal Operation

a Loose Delivery Tube

a

Check and tighten

b Break in tubing

b

Replace as necessary

Water
Droplets in
air stream

c Pump Delivers Excessive Water to

Pads

c

Adjust the Dialflo to reduce the flow

a Inadequate Exhaust

a

Provide more open area to exhaust stale air

Excessive
humidity

b Outside humidity high

b

Turn pump off.

a Dirty Filters

a

Clean

b Dry Filters

b

Check water delivery system. Adjust if
necessary.

Inadequate
Cooling

c Dialflo not set correctly

c

Adjust Dialflo so that the pads have even
saturation.

a Unit located near odor source

a

Remove source

Unpleasant
Odor

b New Celdek filter smell

b

Smell will disappear after a period of
operation.

Rapid
formation of
white
deposits on
pads

High Mineral Content

Bleed off should be set at maximum. More
regular maintenance may be required.