E-4203/E-4204/E-4304

The position of the AMS is important for the proper detection of media
and the label top of form (TOF). The table below indicates suggested
sensor positions for various media types.

Adjustable Media Sensor Position

Media Type

Suggested Sensor Placement

TOF Sensing Used

Continuous*

Near the center of the media

Continuous

Die-cut

Near the center of the label

Gap

Notched

Near the center of the notch

Gap

Reflective

Near the center of the black mark

Reflective

*Label TOF for continuous media is set via the Front Panel (CONT FORM LENGTH) or

software; see Section 4.4.2.


To properly position the AMS, you will need to know where the TOF
mark is located on your media. (For more information on media, see
Specifications).


Depending of your media type, take a measurement from the left-justified
media edge across to the center of the TOF mark as suggested in the
table above. The following example illustrates the measurement of
notched media.

;

Note: Reflective marks are placed on the underside of the media.

Media

Movement

Notch

Left-Justified

Measurement



To simplify the adjustment, the AMS uses Reference Letter designators
that correspond to the following TOF mark distances: