33

• LAMP CONTROL (only with option Ldmx On) - channel: 24 (Stnd) - 24 (16 b) - 28 (Extn)

LAMP ON (FULL POWER)

LAMP ON (FULL POWER)

BIT

%

EFFECT

255

100

180

70.5

0

0.0

101

39.5

100

39.0

LAMP OFF

179

70.0

26

10.0

LAMP OFF

25

9.7

UNUSED RANGE

Lamp ignition after 5 s
in full power levels.

Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.

ON

ON
ON

OFF

ON

OFF

LAMP ON (HALF POWER)

LAMP ON (HALF POWER)

Immediate transition
from full to half power.

Immediate transition
from half to full power.

Lamp ignition not allowed
in half power.

• RESET - channel: 23 (Stnd) - 23 (16 b) - 27 (Extn)

BIT

%

EFFECT

255

100

128

50.0

127

49.7

77

30.0

76 29.7

26 10.0

25

9.7

0 0.0

Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.

COMPLETE RESET
PAN / TILT RESET

PAN / TILT RESET
EFFECTS RESET

EFFECTS RESET

UNUSED RANGE

Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.

Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.

COMPLETE RESET

• PAN FINE - channel: 25 (16 b) - 24 (Extn)

Operation with option Pan Off
(Tilt conventionally represented at 15% and option Tilt

Off)

BIT

%

255

100

0

0.0

Operation with option Pan

On

(Tilt conventionally represented at 15% and option Tilt

Off)

BIT

%

255

100

0

0.0

• TILT FINE - channel: 26 (16 b) - 26 (Extn)

Operation with option Tilt

Off

(Pan conventionally represented at 0% and option Pan

Off)

BIT

%

255

100

0

0.0

Operation with option Tilt

On

(Pan conventionally represented at 0% and option Pan

Off)

BIT

%

255

100

0

0.0

• GOBO 2 FINE - channel: 28 (16 b) - 15 (Extn)

BIT

%

255

100

127

50.0

0

0.0

• GOBO 1 FINE - channel: 27 (16 b) - 12 (Extn)

BIT

%

255

100

127

50.0

0

0.0

Advertising