GOLDEN FOG 1000

GOLDEN FOG 2000 and 2000 DMX

8

TECHNICAL DATA

8

Power supply
200 - 240V 50/60Hz

Input power
GOLDEN FOG 1000:

1,000 VA

GOLDEN FOG 2000:

2,000 VA

GOLDEN FOG 2000 DMX: 2,000 VA

Tank capacity
GOLDEN FOG 1000:

1 litre

GOLDEN FOG 2000 and 2000DMX: 2 litres

Consumption and maximum delivery
GOLDEN FOG 1000:

27 g/min

GOLDEN FOG 2000:

55 g/min

GOLDEN FOG 2000 DMX:

46 g/min

Pre-heating time
GOLDEN FOG 1000: 5 min.÷ 5 min. 30 sec.
GOLDEN FOG 2000: 4 min.÷ 4 min. 30 sec.
GOLDEN FOG

2000 DMX:

4 min.÷ 4 min. 30 sec.

Smoke delivery time
GOLDEN FOG 1000: continuous
GOLDEN FOG 2000: 60”/65”
GOLDEN FOG 2000 DMX: 30 sec. at

100%, continuous with adjustment

CONTROL SYSTEMS

• GOLDEN FOG 1000 - 2000

- Manual control
- Remote manual control
- 0-10V analogue input

• GOLDEN FOG 2000 DMX

- Serial digital input

RS232/423(PMX) or DMX512

- 0-10V analogue input

INDICATORS

• GOLDEN FOG 1000 - 2000

- Machine ready indicator light

on remote control

- Power light

• GOLDEN FOG 2000 DMX

- Power light
- Fluid finished indicator light
- Automatic operation
- DMX signal reception
- PMX signal reception
- Error in receiving signals

SAFETY DEVICES
Power supply automatically cut off in the
event of the boiler overheating.

Weight and dimensions

GOLDEN FOG 1000:

Weight 7.5 Kg (16 lbs 8 ozs)

GOLDEN FOG 2000:

Weight 11 Kg (24 lbs 3 ozs)

GOLDEN FOG 2000 DMX:

Weight 12 Kg (26 lbs 6 ozs)

A mm

270 (10.63”)

310 (12.20”)

B mm

490 (19.29”)

490 (19.29”)

C mm

230 (9.06”)

340 (13.39”)

No mains supply.

Check the supply socket
is powered and/or fuse
conductivity.

Signal transmission cable short-
circuited or disconnected.

Replace cables.

Cannon not properly inserted.

Insert the Cannon on the back
of the machine.

No liquid in tank.

Fill the tank with liquid.

Internal mechanical part broken.

Call an authorized technician.

Tube not inserted properly.

Put the tube back into the tank.

Wrong address.

Check the digital address.

Electronics broken.

Call an authorized technician.

THE LED ON THE REMOTE CONTROL FAILS TO COME ON

THE FITTING WILL NOT SWITCH ON

NO SMOKE IS GENERATED

TROUBLE

THE TUBE FAILS TO DRAW LIQUID

IT FAILS TO WORK WITH DIGITAL SIGNALS

POSSIBLE CAUSES

CHECKS AND REMEDIES