Manual control – Clay Paky ALPHA PROFILE 1500 ST User Manual

Page 23

Advertising
background image

23

ALPHA PROFILE 1500 & ST

BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 6-Ch (6 channel board)
3: 8-Ch (8 channel board)
4: 6-Ch (6 channel board)

DMX MONITOR
Used for displaying the projector DMX channel level in bit (Val) and in
percentage (Perc).

FANS MONITOR
Used for displaying the speed of each fan installed in the projector:
Pwr.Sup (Power supply Fan)
Ball. IN (Ballast IN Fan)
Ball. Out (Ballast OUT Fan)
Eff.IN (Effects IN Fan)
Eff.OUT (Effects OUT Fan)
Lamp (Lamp Fan)
Lamp (Lamp Fan)
Gobo (Gobo Fan)
Board (Yoke Board Fan)

SENSOR STATUS
It lets you check the correct operations of each "sensor” installed in the
projector, each channel is associated with one of the following three
parameters:
• n.a.= sensor not available
• ON= sensor working
• OFF= sensor defective

NETWORK PARAMS
Allows the "Network" parameters of the projector to be displayed or:

IP address: Internet Protocol address (two projectors must not have the
same IP address)
IP mask: 255.0.0.0
Mac address:
Media Access Control: the projector’s Ethernet Address.

LAMP
Used for turning lamp on and off from the projector control panel.
1) Press

F

- the current settings appear on the display (On or Off).

2) Use the UP

B

and DOWN

C

keys to turn the lamp on (On) or off (Off)

3) Press

F

to confirm the selection or LEFT

D

to keep current settings and

return to the top level.

RESET
Used for resetting the projector.
1) Press

F

to reset the projectors, a confirmation message (Are you sure ?)

appears on the display.

2) Select YES to starting reset the fixture or NO to keep the current setting

and return to the top menu level.

CHANNEL
Used for setting channel levels from the projector control panel.
1) Press

F

- the first channel appears on the display.

2) Use the UP

B

and DOWN

C

keys to select the required channel:

3) Press

F

and use the UP

B

and DOWN

C

keys to select the requi-

red DMX level (value between 0 and 255).

4) Press LEFT

D

to return to the top menu level.

Channel

MANUAL CONTROL

Lamp

Manual
Control

On

Off

No

Yes

Reset

Fans

Monitor

Fan

Speed (RPM)

Pwr.Sup

XXXX

Ball.In.

XXXX

Ball.Out

XXXX

Eff.In

XXXX

Eff.Out XXXX
Lamp

XXXX

Lamp

XXXX

Gobo

XXXX

Board

XXXX

Board

Diagnost.

Dmx

Monitor

Board

Status

Err%

0:PT-3f

Good

0.00

1:8-Ch

Good

0.00

2:6-Ch

Good

0.00

3:8-Ch

Good

0.00

4:6-Ch

Good

0.00

Network

params

Sensor

Status

Continue

Advertising
This manual is related to the following products: