VOLTAGE FUSE TYPE

100V 8 AMP SLOW BLOW 5 x 20mm

120V 8 AMP SLOW BLOW 5 x 20mm

220V 4 AMP SLOW BLOW 5 x 20mm

240V 4 AMP SLOW BLOW 5 x 20mm

FOR CONTINUED PROTECTION

AGAINST SHOCK OR FIRE:

1. REPLACE FUSE WITH SAME

TYPE AND RATING

2. DO NOT EXPOSE THIS UNIT

TO RAIN OR MOISTURE

UNBRIDGED

UNBALANCED

BALANCED

UNBALANCED

BALANCED

MAIN POWER

OFF

ON

AC LINE FUSE CHART

FUSE AND VOLTAGE SELECTOR

FUSE VALUE -SEE FUSE CHART

VOLTAGE SELECTION-

SEE OPERATION MANUAL

!

NOTE

SEE SERIAL TAG FOR POWER

REQUIREMENTS, REMOVE POWER

CORD BEFORE CHANGING

FUSE OR LINE VOLTAGE

!

120

AC LINE INPUT

~

T E C H N O L O G I E S I N C .

MODEL

SERIAL NUMBER

VOLTAGE REQUIREMENT

MANUFACTURED IN THE USA

HZ

POWER REQUIREMENT

VA

TO PREVENT ELECTRIC SHOCK, DO NOT

REMOVE COVER. NO USER SERVICEABLE

PARTS INSIDE. REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

CH 1 OUTPUT

CH 2 OUTPUT

CH 3 OUTPUT

CH 4 OUTPUT

CH 1 INPUTS

CH 2 INPUTS

CH 3 INPUTS

CH 4 INPUTS

UNBRIDGED

C A U T I O N

WA R N I N G

!

BRIDGED-CHANNEL 1

AND CHANNEL 2

BRIDGED-CHANNEL 3

AND CHANNEL 4

BRIDGED-DO NOT USE GROUNDS

BRIDGED-DO NOT USE GROUNDS

DO NOT ALLOW AMPLIFIER OUTPUTS

TO COMMON BETWEEN CHANNELS,

OR CONTACT CHASSIS OR INPUT

GROUNDS, OR TO BE CONNECTED

TO ANY ACTIVE CURRENT SOURCE.

THIS PRODUCT
IS DESIGNED,
ENGINEERED
AND BUILT IN THE UNITED
STATES OF AMERICA.

BRIDGED

INPUT

BRIDGED

INPUT

3

3

1

2

2

6

5

4

1

2

2

3

3

DETAILED INSTALLATION

4

I.

Source-Output, Power Connections and Controls

The connectors and controls are clearly marked on the back panel of the AMPLIFIER v10.

Note the correct channel orientation. The function and channel markings on the rear

panel correspond to the front panel controls and their signal paths.

1. The MODE switch selects between unbridged or bridged operation. The default

position is UNBRIDGED. For information on bridging see BRIDGE SETUP.

2. The UNBALANCED and BALANCED inputs should be attached to the appropriate

unbalanced and balanced outputs of a preamplifier either directly or through a

crossover or processor, as appropriate to the application.

3. The CH1 OUTPUT, CH 2 OUTPUT, CH 3 OUTPUT, CH 4 OUTPUT should be attached to four

or three or two speakers. This will depend on how many channels are bridged.
NOTE: THERE ARE NO OUTPUT FUSES SO AS TO INSURE A LOW OUTPUT IMPEDANCE.
SPEAKER PROTECTION IS LEFT TO THE SPEAKER MANUFACTER AS THEY WOULD BEST
KNOW HOW TO PROTECT THEIR SPEAKER.

4. The MAIN POWER switch, once all appropriate connectsions are made, may be left on

as the AMPLIFIER v10 draws a negligible amount of current when the BIAS is turned off.

5. The FUSE AND VOLTAGE SELECTOR houses a 5 X 20 slow blow fuse and voltage selector

cartridge. Should the fuse blow, contact a Coda dealer or call Coda directly. When

changing the fuse, or altering the voltage selection be sure this unit is disconected from

its AC power source.

6. The AC LINE INPUT should be attached to the power cable provided with the amplifier.

After making the appropriate connections insert the three prong safety plug into an

appropriate AC power source. Once the AMPLIFIER v10 is properly connected, the

power switch may be turned on and the led on the front panel will light indicating a ready

state.