Step 12: Tuning

deltamotion.com

23

5. When the wizard is complete, the Gain Calculator will open. Use

the slider bar to choose gains. Begin by pulling the slider close to
the bottom, then click Apply Gains.

6. Use the buttons you previously set up to move the axis back and

forth. The plot will automatically be displayed.

Tip: To halt the axis, click the Fault Controller

button on the

toolbar, or press Ctrl+K.

7. If the Actual Position is not following the Target Position very well,

pull the slider bar up, apply gains, and move the axis again.
Repeat until the Actual Position tracks the Target Position very
well.

Manual Tuning–Position, Pressure, or Force Axes

You can manually tune systems for which autotuning does not work.
For instructions:

1. On the help menu, choose Help Topics.
2. On the Index tab, type tuning and double-click about.
3. The Tuning Overview topic describes tuning.

In the Manual Tuning section, choose a procedure. For most
position control applications, choose Tuning a Hydraulic Position
Axis or Motor in Velocity Mode
. For pressure or force, choose the
procedure that applies to your axis.

After tuning, save the project and update Flash.