Hardware Requirements

The following hardware is required to develop and test a BACnet application on the FT

6050

IzoT Router – required to translate the Ethernet packets to FT-10. This device

acts as an IP packet router but also contains a module that makes the IzoT

Router act as a BACnet Router, per the BACnet standard.

Echelon Series 6000 EVB - for running the demos, and for the development and

testing of a complete BACnet application by the user.

See the FT 6000 EVK Quick Start Guide and Echelon Series 6000 EVB Hardware Guide

for information on using your IzoT Router and EVB with BACnet.

Compiling the BACnet Sample Projects

The sample projects allow you to build the demo that are downloaded and tested to

verify the tool-chain and procedures. It should be done before attempting to link a

user developed application.
There is a BACevb sample project that is intended to run on the Echelon Series 6000

EVB, and which measures and displays space temperature, flashes LEDs and

interacts with the user.
BACsimple is a simplified project to show the minimum viable project using BACnet,

allowing easier integration with the final application.

Procedure
1. The BAClon Toolkit will be installed along with the other IzoT tools. To access

the BACevb sample project, run NodeBuilder, then open the following project:

C:\LonWorks\NeuronC\Examples\BAClon\BACevb\BACdemo.NbPrj

2. Build the project

3. Using NodeUtil, download BACevb.ndl to the Echelon Series 6000 EVB

4. Confirm that it works. On successful startup:

LED1 will illuminate
LED2 will flash
LED1 will go out if SW1 is held down for 1 second. This LED will come on again

each time the system restarts. It can be used to check for system crashes.

5. Set the Domain Table to reflect the IP address choices for your network, or set

DHCP

6. On a PC attached to the network, run the BACnet Browser for IzoT. This should

discover the BACnet Device on the network, and should list the BACnet Objects

contained in it.

(The BACnet Browser for IzoT can be found here:

http://www.connect-ex.com/demos_and_downloads/bacnet-browser-for-

echelons-izot

Note that the FT6050’s device ID and Object Name will be automatically set

based on the IP address of the FT6050. If desired, this can be changed by the