Electrocompaniet ECI 5 User Manual

Page 5

Advertising
background image

5

Replacing a blown main fuse

Diagram 5, page 15

The main fuse is located in a small drawer inside the AC inlet of the unit. If, for some reason

the fuse is blown, turn the unit off, and remove the AC cord from the AC inlet. Open the
drawer with a small screwdriver and remove the blown fuse. The spare fuse is located inside
a holder in front of the main fuse.
1. Remove the spare fuse gently by pushing it sideways out of its holder.
2. Insert the spare fuse as the active fuse.
3. Push the drawer gently back to closed position.
4. Re-insert the AC cord and turn the unit on.

Never replace the fuse with other values than indicated on the unit!

Replacing remote control batteries Diagram 4, page 15

Replace used batteries by gently inserting your fingernail or small screwdriver in the
groove on the left side of the battery compartment cover. Lift the cover off, and insert a
fresh set of batteries. Be careful to follow the + and - polarity indications at the bottom of
the battery compartment.
Battery: 2 x LR03 / AAA: 1.5Volts

Input configurations

Diagram 6, page 15

XLR input:

1 = ground

2 = positive

3 = negative

RCA: Center = positive Circle = ground.

Output configurations

Diagram 6, pg 15 and 1, pg 14

XLR output:

1 = ground

2 = positive

3 = negative

Speaker: Red = positive

Black or White = ground

ECP5XLR:

RCA to XLR adapter: 1 & 3; ground and negative = shorted

2 = positive

Advertising