OPERATING INSTRUCTIONS

The DT-100 is a dynamic transistor and diode tester. It features in-
circuit testing and polarity indicators for both transistors and diodes.
To activate the DT-100, remove the four mounting screws from the
bottom and install a fresh 9V battery.

Diode Testing

1. Place the switch in the diode position.

2. Connect the diode to the red and black leads.

3. Push in the test switch. One diode LED should blink and identify

whether the cathode or anode is connected to the diode (red) lead.

4. If both LED lamps blink, then the diode is shorted.

5. If neither LED lamps light, then the diode is open.

Transistor Mode:

The DT-100 can measure transistors in or out of circuit. It will identify
NPN or PNP by a simple adjustment.

Transistor Testing - Out of Circuit

1. Place the switch in the transistor position.

2. Place the transistor in the socket or attach it to the C, B, and E

leads.

3. Push in the test button. Adjust the base current control so that

the OK LED lights up. This indicates a good transistor.

4. If the OK lamp doesn’t light, adjust the base current control so

that either the NPN or PNP LED lights up. This happens at the
minimum or maximum position of the control setting. This will
indicate transistor type. Place the switch to the NPN position if
the NPN lamp lights up, or place the switch to the PNP position
if the PNP lamp is lit.

5. If no lamps light up, then the transistor is open or we have not

identified the base lead. Repeat assuming another lead at the
base.