Controls – Elenco 100kHz Function Generator User Manual

Page 5

Advertising
background image

CONTROLS

RANGE SWITCHES

Six ranges of frequency are provided by the range switch as shown in Table
1.

Table 1

SINE/TRIANGLE SWITCH

This SINE/TRIANGLE Switch selects the waveform, sine wave or triangle
wave, sent to the SINE/TRIANGLE output terminal.

FREQUENCY MULTIPLIER

The multiplier is a variable control allowing frequency settings between
fixed ranges. The ranges are as shown in Table 1.

AMPLITUDE CONTROL

The Amplitude Control provides amplitude adjustment from near 0 to 3V
or greater for both sine and triangle waveforms.

ON/OFF SWITCH

The ON/OFF Switch turns the power to the FG-500 on or off.

OUTPUT TERMINAL

The output marked SINE/TRIANGLE provides the sine and triangle
waveforms. The output marked SQUARE WAVE provides the square
wave. The output marked GND provides the ground for all output
waveforms.

POSITION TYPICAL FREQUENCY RANGE

1 1Hz - 15Hz
2 10Hz - 150Hz
3 100Hz - 1.5kHz
4 1kHz - 15kHz
5 10kHz - 150kHz
6 100kHz - 1MHz

-4-