3. how to make measurements, Warning, Dc voltage measurement – Elenco Compact Multimeter User Manual

Page 7: Resistance, Audible continuity, Tr h, Diode test

Advertising
background image

5-3. How to Make Measurements

WARNING

1. To avoid electrical shock hazard and/or damage to

the meter, do not measure voltages that might
exceed 500V above earth ground.

2. Before using the instrument, inspect the test leads,

connectors, and probes for cracks, breaks, or
grazes in the insulation.

DC Voltage Measurement

1. Plug the red test lead into the “V

mA” jack and

the black test lead into the “COM” jack.

2. Set the RANGE switch to the desired DCV position.

If the voltage to be measured is not known
beforehand, set the switch to the highest range and
reduce it until a satisfactory reading is obtained.

3. Connect the test leads to the device or circuit being

measured.

4. Turn on the power of the device or circuit being

measured. The voltage value will appear on the
digital display along with the voltage polarity.

Resistance

200

0.1

+(0.8% of rdg+2dgt)

2k

1

+(0.8% of rdg+2dgt)

20k

10

+(0.8% of rdg+2dgt)

200k

100

+(0.8% of rdg+2dgt)

2000k

1k

+(1% of rdg+2dgt)

OVERLOAD PROTECTION: 15 seconds maximum 250Vrms
on all ranges.

MAXIMUM OPEN CIRCUIT VOLTAGE: 3.2V.

Audible Continuity

Built-in buzzer sounds if resistance is
less than 100

.

OVERLOAD PROTECTION: 250Vrms for a maximum of 15
seconds.

TR h

FE

NPN

10

µ

A DC

@3.0V DC

PNP

10

µ

A DC

@3.0V DC

DIODE TEST

Measures forward resistance of a semiconductor
junction in k

at max. test current of 1.5mA.

-10-

-7-

Range

Resolution

Accuracy

Range

Description

Range

Test Condition

Base Current

Advertising