Elenco Regulated 13.8V @ 3A User Manual

Page 2

Advertising
background image

INTRODUCTION

The Model XR-38 has a regulated output of 13.8 volts @ 3A and
capable of handing 5A surges up to 30 minutes. The XR-38 is
designed to power automotive equipment such as CB radios,
stereo systems, mobile two-way radios, and vehicular alarm
systems when removed from the vehicle.

OPERATING PROCEDURE

1. Check the voltage rating of the equipment to be powered.

Care must be taken not to exceed this rating.

2. Turn the power supply OFF.

3. Plug the line cord into a 120V, 60Hz AC outlet.

4. With the power supply turned OFF, connect the load to the

output.

5. Turn the power supply ON.

MAINTENANCE

Fuse replacement

1. Turn power switch off, remove any load on outputs and unplug

the line cord from AC line.

2. Unscrew the fuse holder cap and remove the fuse. Install a new

2A 250V fuse and reattach fuse holder cap.

3. Plug line cord back into 120VAC source and turn the power

switch ON. Check the output for correct voltage.

Thermal

A thermal device inside the transformer will open the primary side
if the internal temperature gets too hot. There should be no output
voltage and the illuminated switch will not light. Follow the steps
below if thermal protection activates.

1. Turn the power switch off and allow unit to cool down. This may

take up to 30 minutes.

2. After the unit cools down, turn the power switch to ON. Check

that the switch lights and the output voltage is 13.8V. The unit is
now ready for operation again.

Specifications

Input

120VAC, 60Hz

Output

13.8VDC @ 3A, 5A surge

Load Regulation

Less than 5%

Ripple

Less than 10mV rms

Output Protection

Thermal and short

Input Protection

2A, 250V fuse

Size

4 5/16” (H) x 6” (W) x 8 3/16”(L)

Weight

5 lbs., 8 oz.

IMPORTANT SAFETY INSTRUCTIONS

1. Save these instructions.

This manual contains important

safety and operating instructions.

2. The XR-38 is thermal, short and fuse protected against server

overloads or shorting of the output terminals. Refer to the
Maintenance

section

for

fuse

or

thermal

protection

information.

3. Service repair should be performed by qualified personnel or

returned to the factory when service or repair is required.
Incorrect reassembly may result in a risk of electrical shock or
fire.

4. Do not expose the power supply to rain or snow. Use only

indoors with normal temperature and humidity.

Advertising