Model ar60t - installation and service, Service – EmberGlo Model AR60T User Manual

Page 2

Advertising
background image

2

EmberGlo

A Division of Midco International Inc

8471 13

Maintenance
Daily as Required

Operation

Installation

1. Position steamer on level surface and plug power cord into 3-hole 120 volt AC grounded

receptacle. If an adapter is used, it must be grounded properly.

2. Pull out water pan and fi ll with distilled (NOT HOT OR BOILING) water to 1/4″ from the top of

the water pan baffl es; then close drawer. Unit is now ready for operation.

3. No Hood Installation Required: According to the Uniform Mechanical Codes per the

International Conference of Building Offi cials Code EmberGlo Steamers do not require a

separate hood for vapor produced during operation. Also, there are no requirements in NSF

Standard 4 (2006e) for steamers to have ventilation.

__________________________________________

1. Move rocker switch to ON position. The ready light will come on, it will take 15-20 minutes to

reach operating temperature.

2. Open food drawer, place food in pan; close drawer and turn dial of timer to time required per

cooking guide. Depress push button at center of timer (ready light will go out) and cycle will

proceed. When the cycle has completed, ready light will come on and buzzer will sound. At the

end of the cycle open drawer and remove food.

3. Manual Operation: Depress square push button switch approximately 1 - 2 seconds.

__________________________________________

The food pan is removed by lifting up. Clean the inside thoroughly and wipe the outside to remove
any material which might have accumulated.
-

To remove the food drawer, pull the drawer out until it stops, release stop located at rear un-

derside of drawer to unlock, and pull out the frame. Wipe the drawer and frame clean and return by
inserting the drawer slide into the slide of the frame, then push the food pan to the rear until the lock
engages automatically.

__________________________________________

DANGER: READ AND UNDERSTAND THIS BULLETIN THOROUGHLY BEFORE

STARTING ANY TROUBLE SHOOTING. AN INADVERTENT SERVICE ERROR COULD RESULT
IN SEVERE PERSONAL INJURY OR DEATH. ONLY A TRAINED EXPERIENCED SERVICE
TECHNICIAN SHOULD ATTEMPT ANY REPAIR PROCEDURE.

Qualifi ed serviced agencies are available at most locations - Refer to EmberGlo listing of AUTHO-
RIZED SERVICE AGENCIES included in Standard Equipment Catalog.

Note: Before attempting service, unplug power cord. For service or examination, all “working parts”
of the steamer are exposed by removing fi rst the cabinet top, then the back. The wiring diagram and
spare cleanout gasket is located on inside of back.

Electric Switch/Thermostat
-

The on-off switch should audibly “click” when operated manually. To determine if electrically

operative, a continuity check should be made.

-

The overheat protection fuse is set for a single use and is non-adjustable and should not be

repaired. Replace if defective with a non-adjustable, non-repairable fuse

-

The thermostat is adjusted at the factory default setting. It is not recommended to re-adjust the

setting. If found defective it is recommended to replace.

Pump System
The pump system is an electrical vibrator type which is controlled by the main timer. It supplies
power to the solid state (#606) recycle timer. A failure in this circuit may be traced from the main
timer thru the solid state timer. Please note that the “on” time of the solid state timer may be as short
as .1 second and then 10 seconds “off” . See the schematic for test points. If the pump is operating
but not pumping, check that the fi lter mounted on the inlet side of pump is not clogged, if so, remove
and clean. If still not streaming, refer to the “Steam Generator” section of this manual.

Timers
There are three timers in this system.
1. Push-button Automatic Reset - times length of cycle in minutes and supplies power to the solid

state timers. To determine if timer is functioning properly a volt meter or test lamp may be used.

See schematic for test points.

2. Solid State Programmable Recycle #606 - times length of shot (.1 second adjustable) and time

between shots (10 seconds adjustable). To determine if timer is functioning properly, a volt

meter or test lamp may be used. See schematic for test points.

Model AR60T - Installation and Service