Es5 series - maintenance and service, Service installation continued, Maintenance as required maintenance daily – EmberGlo ES5 Series User Manual

Page 3

Advertising
background image

EmberGlo

A Division of Midco International Inc

8449 96

3

ES5 Series - Maintenance and Service

Service

Installation

Continued

Recommended Procedure for Understanding the Amount of Steam Generated in both the Manual
and Push Button Types of Steamers:

1. On a cool steamer take the food rack and food pan out of the steamer so that the generator

And water nozzle can be seen.

2. Warm up the unit for 10 to 15 minutes.

3. ES5M & ES5MT - Push the manual lever two to three times

ES5PB & ES5PBS - Push the button long enough to spray water on the generator surface.

4. Watch the water turn into steam. All of the water should evaporate in approximately 20 to

30 seconds.

By pumping the manual lever (ES5M & ES5MT) or pushing the button (ES5PB & ES5PBS) and
watching the time it takes to evaporate the water, the user will learn how to reach the optimal cook-
ing results, whether by pushing the button in or pumping the manual lever.
Timer Type of Steamers - (ES5CTS & ES5CT) - this timing is internally set by the manufacturer to
obtain the optimum cooking steam cycle.

__________________________________________

Food Pan and Grid on all models should be removed and washed with a detergent or run through a
dishwasher.

WARNING: Under no circumstances should the entire steamer be run through a

dishwasher. If any of the switches or components get wet they can malfunction. Never try to
use a device that has been wet— replace it.

WARNING: Perform all maintenance when the unit is cool.

Exterior of unit should be wiped with a damp cloth or cleaned with a stainless steel cleaner.
Water Pan on ES5M, ES5MT, ES5CT, ES5CTS, ES5PB & ES5PBS may be removed for cleaning
by pulling out to stop position; lift front of steamer about 3″ to clear pump and pull pan all the way
out. To replace, lift front of steamer about 3″, slide pan in pan track until it is about 2″ from closed
position, then lower steamer front and push pan completely in.

__________________________________________

Generator: The cavity in the generator may accumulate lime and is cleaned by scraping or wire
brushing. Do not remove all of this deposit since a thin coating improves steaming.
Water Nozzle: The water nozzle, the round cap in front center of generator, may be pulled out for
cleaning. Clean small holes and inside of tube with spring clip provided in the tube.
Water Inlet: If the tube through generator is limed, remove plug at bottom and push lime out with a
wire or small rod.
Strainers:

ES5M ES5MT, : Strainer is in bottom of pump. Remove wire ring, then strainer wash and

replace.

ES5CTS & ES5PBS: Strainer is located in front center of bottom. Slip strainer off

Tube, wash and replace.

ES5PB & ES5CT: To wash strainer located in hose:

1. Remove hose.

2. Remove quick connect fi tting.

3. Reverse hose (connect steamer end to supply valve). Drain into sink or bucket.

4. Run water through hose to clean.

5. Return to original connections.

There is a strainer in inlet of solenoid valve that normally does not require cleaning but under
extreme conditions may have to be removed and cleaned.

__________________________________________

DANGER: Before attempting service, unplug power cord.

We recommend any service be done by qualifi ed service personnel. Refer to separate Parts List for
parts identifi cation and assembly guide.
1. All electrical components are contained in enclosure behind switch panel. For access,

remove sloping front and switch panel.

2. ES5M & ES5MT pump is easily removed for service or replacement. Disconnect water line

(under steamer) from pump, open electric enclosure, disconnect linkage and remove two

screws holding pump.

3. To remove ES5CTS & ES5PBS pump:

A.

Disconnect electric wires from terminals.

B.

Disconnect discharge hose from pump.

C.

Remove two screws through bottom of steamer holding pump bracket.

D.

Lift pump out.