Testing Fibers

OTDR

51

Launch Conditions for Multimode Measurements

The table on fiber types gives information about tests with the 50 μm and
62.5 μm fibers.

Fiber type

Recommended mode filter

Remarks

50 μm

Perform a five-turn

mandrel-wrap (wrapping the

patchcord a minimum of five

turns around the mandrel tool)

on the patchcord connecting

the OTDR to the fiber under

test.
As per FOTP-34:

³

For fibers with 3 mm

jacket: use a mandrel tool

with a diameter of 25 mm.

³

For fibers without jacket:

use a mandrel tool with a

diameter of 22 mm.

Nominal launch conditions are

overfilled.
Loss measurements can be

slightly pessimistic (higher loss)

when compared to loss

measurements done with a

50 MMF source compliant to

FOTP34, Method A2.

62.5 μm

No mode filter required.

Loss measurements similar to

those obtained with a power

meter and a source that is

conditioned according to

FOTP34, Method A2.

I

MPORTANT

If you test with 50-μm fibers, EXFO recommends that you use a
mode filter (mandrel-wrap). Otherwise, you may obtain results with
an excess loss value of 0.1 to 0.3 dB.