EXFO FTB-200 v2 Compact Modular Platform User Manual

Page 26

Advertising
background image

Safety Information

16

FTB-200 v2

Electrical Safety Information

Equipment Ratings

Temperature

Operation

unit powered by battery: 0 °C to 50 °C

a

(32 °F to 122 °F)

unit connected to AC adapter: 5 °C to 40 °C

(41 °F to 104 °F)

a.

With FTB-8XXX modules, the maximum operation temperature is 40 °C (104 °F).

Storage

unit without battery: –40 °C to 70 °C

b

(–40 °F to 158 °F)

unit with battery: –20 °C to 60 °C (–4 °F to 140 °F)

AC adapter: –20 °C to 60 °C (–4 °F to 140 °F)

b.

With FTB-8XXX modules, the maximum storage temperature is 50 °C (122 °F).

Relative humidity

c

c.

Measured in 0 °C to 31 °C (32 °F to 87.8 °F) range, decreasing linearly to 50 % at 40 °C (104 °F).

unit:  95 % non-condensing

AC adapter: 10 % to 80 % non-condensing

Maximum operation altitude

2000 m (6562 ft) (unit connected to external power

supply)

5000 m (16405 ft) (unit operated from battery)

Pollution degree

2 (unit connected to external power supply)

3 (unit operated from battery)

d

d.

Equipment must be normally protected against exposure to direct sunlight, precipitation and full wind

pressure.

Overvoltage category

unit: I

AC adapter: II

Measurement category

Not rated for measurement categories II, III, or IV

Input power

e

e.

Not exceeding ± 10 % of the nominal voltage.

unit: 24 V;4 A